Reliability of an Accelerometer-Based System for Quantifying Multiregional Spinal Range of Motion
- 1 May 2015
- journal article
- Published by National University of Health Sciences in Journal of Manipulative and Physiological Therapeutics
- Vol. 38 (4) , 275-281
Abstract
The purpose of this study was to investigate the reliability of a novel motion analysis device for measuring the regional breakdown of spinal motion and describing the relative motion of different segments of the thoracolumbar (TL) spine. Two protocols were applied to 18 healthy participants. In protocol 1, 2 sensors were placed on the forehead and T1 to measure cervical range of motion (ROM). In protocol 2, 6 sensors were placed on the spinous processes of T1, T4, T8, T12, L3, and S1 to measure TL regional ROM. Intraclass correlation coefficients were used to evaluate the repeatability of movement, whereas SEM was used to define the extent of error. Ranges of motion were demonstrated in flexion extension, right-left lateral flexion, and right-left rotation of the head-cervical, upper thoracic, middle thoracic, lower thoracic, upper lumbar, and lower lumbar. The intraclass correlation coefficient values, for all regions, were found to be high, ranging from 0.88 to 0.99 for all movements, and regions of the spine and SEM values ranged from 0.4° to 5.2°. Multiregional spine ROM ranged from 3° in the upper thoracic and mid-thoracic during flexion and 80° at head cervical during right rotation. The described methodology was reliable for assessing regional spinal ROM across multiple spinal regions while providing the relative motions of different segments of the TL spine.Keywords
This publication has 37 references indexed in Scilit:
- Normal kinematics of the neck: The interplay between the cervical and thoracic spinesManual Therapy, 2013
- Back Pain Is Associated With Changes in Loading Pattern Throughout Forward and Backward BendingSpine, 2010
- A Systematic Review of Reliability and Validity Studies of Methods for Measuring Active andPassive Cervical Range of MotionJournal of Manipulative and Physiological Therapeutics, 2010
- Caution: The use of an electromagnetic device to measure trunk kinematics on rowing ergometersSports Biomechanics, 2009
- From neuromuscular activation to end-point locomotion: An artificial neural network-based technique for neural prosthesesJournal of Biomechanics, 2009
- Inclination measurement of human movement using a 3-D accelerometer with autocalibrationIEEE Transactions on Neural Systems and Rehabilitation Engineering, 2004
- A new skin-surface device for measuring the curvature and global and segmental ranges of motion of the spine: reliability of measurements and comparison with data reviewed from the literatureEuropean Spine Journal, 2004
- Reliability: What is it, and how is it measured?Physiotherapy, 2000
- Accuracy of an electromagnetic tracking device: A study of the optimal operating range and metal interferenceJournal of Biomechanics, 1996
- Analysis of data from multiclinic trialsControlled Clinical Trials, 1986