Abstract
The development of intimal hyperplasia following stent deployment can lead to narrowing or even occlusion of the stent lumen. The underlying mechanisms leading to neointimal proliferation within stents remain largely unknown. Long‐term evaluation of stent patency requires a noninvasive means for assessing the stent lumen. MR angiography (MRA) has shown potential to provide noninvasive assessment of the vascular system. However, a detailed assessment of the stent lumen with MRI is often hampered by material‐dependent susceptibility artifacts, as well as by radiofrequency (RF) eddy currents generated inside the electrically conducting stent mesh. In this study, stent prototypes were designed to act as active resonant structures at the Larmor frequency of the MR system. Employing the principle of inductive coupling, the B1 fields of the stents were coupled to that of an outside surface coil. The stents thus acted as local RF signal amplifiers. Various stent designs were investigated regarding their coupling to an external coil, signal homogeneity, and suitability for mechanical expansion for implantation purposes. The dependency of flip angle amplification on the quality factor Q of the stents was systematically investigated. Phantom experiments revealed signal amplification in all stent prototypes. Signal enhancement inside and close to the surface of the stents enabled their localization with high contrast in MR images. In vivo imaging experiments in the iliac, renal, and splenic arteries of two pigs confirmed the in vitro findings. Wireless active visualization of stents allows for detailed analysis of the stent lumen with high contrast and spatial resolution. The proposed method could thus provide a powerful diagnostic means for the noninvasive long‐term follow‐up of stent patency, thereby enhancing our understanding of the mechanisms of restenosis. Magn Reson Med 48:781–790, 2002.Keywords
This publication has 41 references indexed in Scilit:
- In-stent Restenosis: The Washington Hospital Center Experience 11Supported in part by Medlantic Research Institute, Washington, DC, and Cardiology Research Foundation, Washington, DC.The American Journal of Cardiology, 1998
- Pathobiologic Responses to Stenting 11Supported in part by grants from the National Institutes of Health (GM/HL49039 and HL03104), the Burroughs Wellcome Fund for Experimental Therapeutics, Durham, North Carolina, and the Whitaker Foundation, Rosslyn, Virginia.The American Journal of Cardiology, 1998
- Tuned fiducial markers to identify body locations with minimal perturbation of tissue magnetizationMagnetic Resonance in Medicine, 1996
- Impact of plaque morphology and composition on the mechanisms of lumen enlargement using intracoronary ultrasound and quantitative angiography after balloon angioplastyThe American Journal of Cardiology, 1996
- MR Microscopy of the Rat Carotid Artery after Balloon Injury by Using an Implanted Imaging CoilMagnetic Resonance in Medicine, 1995
- Coronary restenosis: Evaluation of a restenosis injury index in a swine modelAmerican Heart Journal, 1993
- The Pathogenesis of Coronary Artery Disease and the Acute Coronary SyndromesNew England Journal of Medicine, 1992
- Inductive coupling and tuning in NMR probes; ApplicationsJournal of Magnetic Resonance (1969), 1988
- Some observations of the design of rf coils for human internal useMagnetic Resonance in Medicine, 1988
- Wireless implanted magnetic resonance probes for in vivo NMRJournal of Magnetic Resonance (1969), 1986