Reproducibility of computed tomography angiography data analysis using semiautomated plaque quantification software: implications for the design of longitudinal studies
- 7 December 2012
- journal article
- research article
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 29 (5) , 1095-1104
Abstract
Reproducibility of the quantitative assessment of atherosclerosis by computed tomography coronary angiography (CTCA) is paramount for the design of longitudinal studies. The purpose of this study was to assess the inter- and intra-observer reproducibility using semiautomated CT plaque analysis software in symptomatic individuals. CTCA was performed in 10 symptomatic patients after percutaneous treatment of the culprit lesions and was repeated after 3 years. The plaque quantitative analysis was performed in untreated vessels with mild-to-moderate atherosclerosis and included geometrical and compositional characteristics using semiautomated CT plaque analysis software. A total of 945 matched cross-sections from 21 segments were analyzed independently by a second reviewer to assess inter-observer variability; the first observer repeated all the analyses after 3 months to assess intra-observer variability. The observer variability was also compared to the absolute plaque changes detected over time. Agreement was evaluated by Bland–Altman analysis and concordance correlation coefficient. Inter-observer relative differences for lumen, vessel, plaque area and plaque burden were 1.2, 0.6, 2.2, 1.6 % respectively. Intra-observer relative differences for lumen, vessel, plaque area and plaque burden were 1.0, 0.4, 0.2, 0.4 % respectively. For the average plaque attenuation values the inter- and intra-observer variability was 5 and 2 % respectively. For the % low-attenuation-plaque the inter- and intra-observer variability was 16 and 6 % respectively. The absolute intra-observer variability for the plaque burden was 1.30 ± 1.09 %, while the temporal plaque burden difference was 3.55 ± 3.02 % (p = 0.001). The present study shows that the geometrical assessment of coronary atherosclerosis by CTCA is highly reproducible within and between observers using semiautomated quantification software and that serial plaque changes can be detected beyond observer variability. The compositional measurements are more variable between observers than geometrical measurements.Keywords
This publication has 21 references indexed in Scilit:
- Natural History of Coronary Atherosclerosis by Multislice Computed TomographyJACC: Cardiovascular Imaging, 2012
- Clinical expert consensus document on standards for acquisition, measurement and reporting of intravascular ultrasound regression/progression studiesEuroIntervention, 2011
- Assessment of Coronary Plaque Progression in Coronary Computed Tomography Angiography Using a Semiquantitative ScoreJACC: Cardiovascular Imaging, 2009
- Reproducibility of volumetric intravascular ultrasound radiofrequency-based analysis of coronary plaque composition in vivoThe International Journal of Cardiovascular Imaging, 2008
- Assessment of Changes in Non-Calcified Atherosclerotic Plaque Volume in the Left Main and Left Anterior Descending Coronary Arteries over Time by 64-Slice Computed TomographyThe American Journal of Cardiology, 2008
- Influence of a Lipid-Lowering Therapy on Calcified and Noncalcified Coronary Plaques Monitored by Multislice Detector Computed TomographyInvestigative Radiology, 2007
- Reproducibility of intravascular ultrasound radiofrequency data analysis: implications for the design of longitudinal studiesThe International Journal of Cardiovascular Imaging, 2006
- Principles for National and Regional Guidelines on Cardiovascular Disease PreventionCirculation, 2004
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart AssociationCirculation, 1975