Uncertainty evaluation in the analysis of biological samples by sector field inductively coupled plasma mass spectrometry. Part B: measurements of As, Co, Cr, Mn, Mo, Ni, Sn and V in human serum
- 7 January 2011
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 25 (3) , 453-458
Abstract
This protocol was developed to estimate the uncertainty of measurements in the sector field inductively coupled plasma mass spectrometry analysis of As, Co, Cr, Mn, Mo, Ni, Sn and V in human serum by utilizing in‐house validation data. The approach is outlined in the Eurachem/Citac Guide and other relevant publications. The results generated were the followings: (i) coefficients of regression >0.9995 over two orders of magnitude of metal concentration; (ii) method quantification limits between 0.05 µg/L (Cr, Mn) and 0.49 µg/L (As); (iii) mean trueness checked against a certified reference material between 95.4% (As) and 107.7% (Ni); (iv) repeatability better than 10.2% over the range 0.1–2.0 µg/L; (v) reproducibility better than 12.0% over the range 0.1–2.0 µg/L; and (vi) expanded uncertainty budget comprised between 14.7% (Mn) and 27.9% (Cr) over the range 0.1–2.0 µg/L. Copyright © 2011 John Wiley & Sons, Ltd.Keywords
This publication has 11 references indexed in Scilit:
- Uncertainty evaluation in the analysis of biological samples by sector field inductively coupled plasma mass spectrometry. Part A: measurements of Be, Cd, Hg, Ir, Pb, Pd, Pt, Rh, Sb, U, Tl and W in human serumRapid Communications in Mass Spectrometry, 2010
- From GUM to alternative methods for measurement uncertainty evaluationAccreditation and Quality Assurance, 2009
- Use of recovery and bias information in analytical chemistry and estimation of its uncertainty contributionTrAC Trends in Analytical Chemistry, 2008
- Nickel quantification in serum by a validated sector‐field inductively coupled plasma mass spectrometry method: assessment of tentative reference values for an Italian populationRapid Communications in Mass Spectrometry, 2006
- Uncertainty of inductively coupled plasma mass spectrometry based measurements: an application to the analysis of urinary barium, cesium, antimony and tungstenRapid Communications in Mass Spectrometry, 2005
- The evaluation of measurement uncertainty from method validation studiesAccreditation and Quality Assurance, 2000
- The evaluation of measurement uncertainty from method validation studiesAccreditation and Quality Assurance, 2000
- Estimating uncertainties of analytical results using information from the validation processAnalytica Chimica Acta, 1999
- Using validation data for ISO measurement uncertainty estimationPart 1. Principles of an approach using cause and effect analysisThe Analyst, 1998
- Harmonized guidelines for internal quality control in analytical chemistry laboratories (Technical Report)Pure and Applied Chemistry, 1995