Viscoless microincision cataract surgery
Author:
Open Access
- 1 June 2008
- journal article
- other
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. 2 (4) , 717-721
Abstract
Viscoless microincision cataract surgery Guy SalletDepartment of Opthamology, Aalsters Stedelijk Ziekenhuis, Belgium A cataract surgery technique is described in which incisions, continuous circular capsulorhexis and hydrodissection are made without the use of any viscoelastics. Two small incisions are created through which the different parts of the procedure can take place, maintaining a stable anterior chamber under continuous irrigation. Subsequent bimanual phacoemulsification can be done through these microincisions. At the end of the procedure, an intraocular lens can be inserted through the self-sealing incision under continuous irrigation. 50 consecutive cataract patients were operated on without the use of viscoelastics and then compared with a group of 50 patients who had been helped with viscoelastics. No difference in outcome, endothelial cell count or pachymetry was noted between the two groups. No intraoperative complication was encountered. Viscoless cataract surgery was a safe procedure with potential advantages.Keywords: ophthalmic visco-surgical device, viscoless cataract surgery, microincisionKeywords
This publication has 17 references indexed in Scilit:
- Corneal Endothelium Evaluation After Phacoemulsification With Continuous Anterior Chamber InfusionCornea, 2005
- Retained ophthalmic viscosurgical device material in the capsular bag 6 months after phacoemulsificationJournal of Cataract & Refractive Surgery, 2005
- Increased Intraocular Pressure and Corneal Endothelial Cell Loss Following Phacoemulsification SurgeryOphthalmic Surgery, Lasers and Imaging Retina, 2004
- Corneal edema and intraocular pressure after cataract surgeryJournal of Cataract & Refractive Surgery, 2004
- Removal times for a dispersive and a cohesive ophthalmic viscosurgical device correlated with intraocular lens materialJournal of Cataract & Refractive Surgery, 2004
- Removal times and techniques of a viscoadaptive ophthalmic viscosurgical deviceJournal of Cataract & Refractive Surgery, 2004
- Anterior chamber maintainer versus viscoelastic material for intraocular lens implantation: case-control studyJournal of Cataract & Refractive Surgery, 2001
- Intraokulardruck nach Phakoemulsifikation mit Implantation einer Silicon-Plattenhaptik-Intraokularlinse ohne Viskoelastika12Klinische Monatsblätter für Augenheilkunde, 2000
- Implantation of a Staar silicone intraocular lens with the anterior chamber maintainerJournal of Cataract & Refractive Surgery, 1996
- Using an anterior chamber maintainer to control intraocular pressure during phacoemulsificationJournal of Cataract & Refractive Surgery, 1994