Human Blood Pressure Simulation for Stress Analysis in Model of Vasculature Using Photoelastic Effect
Authors:
- Carlos TerceroCTCarlos Tercero
- Seiichi IkedaSISeiichi Ikeda
- Erick TijerinoETErick Tijerino
- Motoki MatsushimaMMMotoki Matsushima
- Toshio FukudaTFToshio Fukuda
- Makoto NegoroMNMakoto Negoro
- Ikuo TakahashiITIkuo Takahashi
- 5 September 2009
- journal article
- Published by Fuji Technology Press Ltd. in International Journal of Automation Technology
- Vol. 3 (5) , 533-540
Abstract
Numerical criteria for evaluating stress on vasculature models have applications in evaluating medical tools and surgical skills enabling better endovascular surgery training and the development of better medical techniques and tools. We propose using the stress produced by blood pressure simulation in the vasculature model wall for this criterion and use photoelastic effect for measuring the principal stress magnitude component. We simulated human blood pressure with 5.6% average error and developed shielded urethane model of vasculature enabling water circulation and avoiding plastic deformation at pressures below 182 mmHg. We developed software to calculate model wall stress. We quantitatively compared in four ranges stress produced on the model wall by blood pressure simulation and a guide wire.Keywords
This publication has 16 references indexed in Scilit:
- Patient-Specific IVR Endovascular Simulator with Augmented Reality for Medical Training and Robot EvaluationJournal of Robotics and Mechatronics, 2008
- Numerical evaluation method for catheter prototypes using photo-elastic stress analysis on patient-specific vascular modelThe International Journal of Medical Robotics and Computer Assisted Surgery, 2007
- Arterial Blood Pressure System Modeling and Signal Analysis2007
- The role of medical simulation: an overviewThe International Journal of Medical Robotics and Computer Assisted Surgery, 2006
- An In Vitro Patient-Specific Biological Model of the Cerebral Artery Reproduced with a Membranous Configuration for Simulating Endovascular InterventionJournal of Robotics and Mechatronics, 2005
- High-Normal Blood Pressure — More “High” Than “Normal”New England Journal of Medicine, 2001
- Endovascular Occlusion of Intracranial Aneurysms with Guglielmi Detachable Coils: Correlation Between Coil Packing Density and Coil CompactionActa Neurochirurgica, 2001
- Alternative projections of mortality and disability by cause 1990–2020: Global Burden of Disease StudyThe Lancet, 1997
- Simultaneous Coronary Pressure and Flow Velocity Measurements in HumansCirculation, 1996
- A Comparison of Balloon-Expandable-Stent Implantation with Balloon Angioplasty in Patients with Coronary Artery DiseaseNew England Journal of Medicine, 1994