Objective: To explore the efficacy and safety of intermittent use of flash glucose monitoring (FGM) for improving glycemic control in Chinese elderly patients with type 2 diabetes mellitus (T2DM). Methods: This is a prospective observational study involving patients with T2DM aged ≥ 60 years. The study period spans 12 weeks, with participants wearing FGM at weeks 0, 5, and 10. Participants were divided into two subgroups based on HbA1c at enrollment: < 7.0% and ≥ 7.0%. The primary outcome of the study was HbA1c level. Secondary outcomes included time in range (3.9– 10mmol/L) (TIR), time below range (< 3.9mmol/L) (TBR), time above range (> 10.0mmol/L) (TAR), and glycemic variability (GV). Results: A total of 68 patients completed the 12-week FGM follow-up (age 67.9 ± 5.2 years; BMI 25.4 ± 3.3kg/m²). Overall findings revealed that compared to baseline, HbA1c decreased from 7.81 ± 1.25% to 7.44± 1.10% after 12 weeks of intermittent wearing of FGM (p < 0.001). In the subgroup analysis with HbA1c ≥ 7.0%, the results showed a significant reduction in HbA1c of 0.51mmol/L after 12 weeks (8.36 ± 0.95% vs 7.75 ± 0.97%, p < 0.001). And there was a significant reduction in TBR in the subgroup with HbA1c < 7% (p = 0.028). Multiple linear regression analysis showed that the baseline HbA1c (β = − 0.529, P< 0.001), duration of T2DM (β = 0.341, P = 0.001), and the frequency of sensor use (β = − 0.269, P = 0.043) were associated with the reduction in HbA1c level. Conclusion: Intermittent use of FGM is associated with an improvement in glycemic outcomes and reduces the risk of hypoglycemia in Chinese elderly patients with T2DM.Keywords
This publication has 31 references indexed in Scilit:
- Epidemiology of Diabetes Mellitus and Cardiovascular DiseaseCurrent Cardiology Reports, 2019
- 12. Older Adults: Standards of Medical Care in Diabetes—2019Diabetes Care, 2018
- The Legacy Effect in Type 2 Diabetes: Impact of Early Glycemic Control on Future Complications (The Diabetes & Aging Study)Diabetes Care, 2018
- Baseline Glycated Hemoglobin Values Predict the Magnitude of Glycemic Improvement in Patients with Type 1 and Type 2 Diabetes: Subgroup Analyses from the DIAMOND Study ProgramDiabetes Technology & Therapeutics, 2018
- The Effect of Reduced Self-Monitored Blood Glucose Testing After Adoption of Continuous Glucose Monitoring on Hemoglobin A1c and Time in RangeData reported previously in Price, DA, et al. (2017). Glycemic impact of reduced frequency of blood glucose monitoring with continuous glucose monitoring use. Diabetes 66(S1):A239.Diabetes Technology & Therapeutics, 2018
- Flash Glucose-Sensing Technology as a Replacement for Blood Glucose Monitoring for the Management of Insulin-Treated Type 2 Diabetes: a Multicenter, Open-Label Randomized Controlled TrialDiabetes Therapy, 2016
- How Patients With Type 1 Diabetes Translate Continuous Glucose Monitoring Data into Diabetes Management DecisionsEndocrine Practice, 2015
- Hypoglycemia Unawareness in Older Compared With Middle-Aged Patients With Type 2 DiabetesDiabetes Care, 2009
- Continuous Glucose Monitoring and Intensive Treatment of Type 1 DiabetesNew England Journal of Medicine, 2008
- Association of glycaemia with macrovascular and microvascular complications of type 2 diabetes (UKPDS 35): prospective observational studyBMJ, 2000