Temporary Structural Health Monitoring of Historical Széchenyi Chain Bridge
Open Access
Abstract
A temporary monitoring system was installed on the 175-year-old historical Széchenyi Chain Bridge during its reconstruction. The bridge is in the downtown area in the capital city of Hungary and plays a significant role in the city life of Budapest. Six-month-long measurements were conducted during the reconstruction process of the bridge, yielding crucial insights into the structural behaviour of the historical structure. The measurement results were evaluated; the findings encompass the rotation capacity of the pins between the chain elements and the structural response to temperature changes. This information helped the decision-making between 2021 and 2023 by the designers and construction company during the reconstruction. For instance, daily temperature fluctuations resulted in increased bending moments in the chain elements, rising up to 158% compared to the values observed during a proof load test in 2018. Furthermore, the measurements reveal an approximate 42% increase in normal forces compared to the proof load test, which highlights the high sensitivity of chain bridges to temperature fluctuations, where geometric stiffness plays a crucial role. Reconstruction, namely reducing self-weight, notably intensifies the impact on normal forces and bending moments. These outcomes strongly emphasize the dominance of the dead load and self-weight in the case of chain bridges.Keywords
All Related Versions
Funding Information
- Magyar Tudományos Akadémia (LP2021-06/2021)
This publication has 20 references indexed in Scilit:
- Optimal static strain sensor placement for truss bridgesInternational Journal of Distributed Sensor Networks, 2017
- Fiber optic health monitoring and temperature behavior of bridge in cold regionStructural Control and Health Monitoring, 2017
- The state of the art in structural health monitoring of cable-stayed bridgesJournal of Civil Structural Health Monitoring, 2015
- Fatigue Damage Evolution and Monitoring of Carbon Fiber Reinforced Polymer Bridge Cable by Acoustic Emission TechniqueInternational Journal of Distributed Sensor Networks, 2012
- Reliability assessment of cable-stayed bridges based on structural health monitoring techniquesStructure and Infrastructure Engineering, 2012
- Monitoring and Failure Analysis of Corroded Bridge Cables under Fatigue Loading Using Acoustic Emission SensorsSensors, 2012
- Experimental and Numerical Study of the Fatigue Properties of Corroded Parallel Wire CablesJournal of Bridge Engineering, 2012
- Integration of structural health monitoring in a system performance based life-cycle bridge management frameworkStructure and Infrastructure Engineering, 2010
- Uncertainty quantification in the damage assessment of a cable-stayed bridge by means of fuzzy numbersComputers & Structures, 2009
- Modal identification of bridges under varying environmental conditions: Temperature and wind effectsStructural Control and Health Monitoring, 2009