Monitoring of Remotely Reprogrammable Implantable Loop Recorders With Algorithms to Reduce False‐Positive Alerts
Open Access
- 5 March 2024
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 13 (5) , e032890
Abstract
Background: Implantable loop recorders (ILRs) are increasingly placed for arrhythmia detection. However, historically, ≈75% of ILR alerts are false positives, requiring significant time and effort for adjudication. The LINQII and LUX‐Dx are remotely reprogrammable ILRs with dual‐stage algorithms using artificial intelligence to reduce false positives, but their utility in routine clinical practice has not been studied. Methods and Results: We identified patients with the LINQII and LUX‐Dx who were monitored by the Veterans Affairs National Cardiac Device Surveillance Program between March and June 2022. ILR programming was customized on the basis of implant indication. All alerts and every 90‐day scheduled transmissions were manually reviewed. ILRs were remotely reprogrammed, as appropriate, after false‐positive alerts or 2 consecutive same‐type alerts, unless there was ongoing clinical need for that alert. Outcomes were total number of transmissions and false positives. We performed medical record review to determine if patients experienced any adverse clinical events, including hospitalization and mortality. Among 117 LINQII patients, there were 239 total alerts, 43 (18.0%) of which were false positives. Among 105 LUX‐Dx patients, there were 300 total alerts, 115 (38.3%) of which were false positives. LINQIIs were reprogrammed 22 times, resulting in a decrease in median alerts/day from 0.13 to 0.03. LUX‐Dx ILRs were reprogrammed 52 times, resulting in a decrease from 0.15 to 0.01 median alerts/day. There were no adverse clinical events that could have been identified by superior or earlier arrhythmia detection. Conclusions: ILRs with artificial intelligence algorithms and remote reprogramming ability are associated with reduced alert burden because of higher true‐positive rates than prior ILRs, without missing potentially consequential arrhythmias.Keywords
This publication has 16 references indexed in Scilit:
- 2023 HRS/EHRA/APHRS/LAHRS expert consensus statement on practical management of the remote device clinicHeart Rhythm, 2023
- Preliminary results from the LUX‐Dx insertable cardiac monitor remote programming and performance (LUX‐Dx PERFORM) studyClinical Cardiology, 2022
- Artificial intelligence augments detection accuracy of cardiac insertable cardiac monitors: Results from a pilot prospective observational studyCardiovascular Digital Health Journal, 2022
- Factors associated with remote monitoring adherence for cardiovascular implantable electronic devicesHeart Rhythm, 2022
- Resource Use and Economic Implications of Remote Monitoring With Subcutaneous Cardiac Rhythm MonitorsJACC: Clinical Electrophysiology, 2021
- Remote Monitoring Alert BurdenJACC: Clinical Electrophysiology, 2021
- Comparison of the Effect of Atrial Fibrillation Detection Algorithms in Patients With Cryptogenic Stroke Using Implantable Loop RecordersThe American Journal of Cardiology, 2020
- Incidence of false-positive transmissions during remote rhythm monitoring with implantable loop recordersHeart Rhythm, 2020
- Implantable loop recorder in clinical practiceJournal of Arrhythmia, 2018
- HRS Expert Consensus Statement on remote interrogation and monitoring for cardiovascular implantable electronic devicesHeart Rhythm, 2015