Optimal Actuator Placement for Active Vibration Control With Known Disturbances
- 1 September 1999
- journal article
- research article
- Published by SAGE Publications in Journal of Vibration and Control
- Vol. 5 (5) , 709-724
Abstract
Two cost functions, based on the disturbance sensitivity grammian, are presented that can be used to find the optimal position of an active vibration control actuator. The disturbance sensitivity grammian is a novel parameter in the field of active vibration control, and by minimizing the "size" of this matrix, one can maximize the effectiveness of the actuator to control the structure in a closed-loop configuration. Two examples—a pinned-pinned beam and an L-shaped membrane—are used to demonstrate the applicability of the criterion. It turns out that the optimal position is very close to where the disturbance acts on the system. The criterion is also not sensitive to the assumed damping included in the model.Keywords
This publication has 8 references indexed in Scilit:
- Sensor And Actuator Location In Motion Control Of Flexible StructuresJournal of Sound and Vibration, 1993
- Sensor/actuator placement for flexible space structuresIEEE Transactions on Aerospace and Electronic Systems, 1993
- Sensor-Actuator Placement for Flexible Structures with Actuator DynamicsJournal of Guidance, Control, and Dynamics, 1993
- Method for optimal actuator and sensor placement for large flexible structuresJournal of Guidance, Control, and Dynamics, 1992
- Measures of modal controllability and observability for first- and second-order linear systemsJournal of Guidance, Control, and Dynamics, 1989
- Dislocated actuator/sensor positioning and feedback design for flexible structuresJournal of Guidance, Control, and Dynamics, 1983
- Controllability measures and actuator placement in oscillatory systemsInternational Journal of Control, 1981
- Controllability and Observability of Linear Matrix-Second-Order SystemsJournal of Applied Mechanics, 1980