Site of deposition and factors affecting clearance of aerosolized solute from canine lungs
Authors:
- N. W. RizkNRN. W. Rizk
- J. M. LuceJLJ. M. Luce
- J. M. HoeffelJHJ. M. Hoeffel
- D. C. PriceDPD. C. Price
- J. F. MurrayJMJ. F. Murray
- 1 March 1984
- journal article
- research article
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 56 (3) , 723-729
Abstract
We determined the influence of several factors on lung solute clearance using aerosolized 99mTc-diethylenetriaminepentaacetate. We used a jet nebulizer-plate separator-balloon system to generate particles with an activity median aerodynamic diameter of 1.1 micron, administered the aerosol in a standard fashion, and determined clearance half times (t1/2) with a gamma-scintillation camera. The following serial studies were performed in five anesthetized, paralyzed, intubated, mechanically ventilated dogs: 1) control, with ventilatory frequency (f) = 15 breaths/min and tidal volume (VT) = 15 ml/kg during solute clearance; 2) repeat control, for reproducibility; 3) increased frequency, with f = 25 breaths/min and VT = 10 ml/kg; 4) positive end-expiratory pressure (PEEP) of 10 cmH2O; 5) unilateral pulmonary arterial occlusion (PAO); and 6) bronchial arterial occlusion (BAO). Control t1/2 was 25 +/- 5 min and did not change in the repeat control, increased frequency, or BAO experiments. PEEP markedly decreased t1/2 to 13 +/- 3 min (P less than 0.01), and PAO increased it to 37 +/- 6 min (P less than 0.05). We conclude that clearance from the lungs by our method is uninfluenced by increased frequency, increases markedly with PEEP, and depends on pulmonary, not bronchial, blood flow.Keywords
This publication has 15 references indexed in Scilit:
- Rapid improvement in abnormal pulmonary epithelial permeability after stopping cigarettesBMJ, 1981
- Response of alveolar epithelial solute permeability to changes in lung inflationJournal of Applied Physiology, 1980
- INCREASED ALVEOLAR EPITHELIAL PERMEABILITY IN CIGARETTE SMOKERSThe Lancet, 1980
- ACCELERATED CLEARANCE OF SMALL SOLUTES FROM THE LUNGS IN INTERSTITIAL LUNG-DISEASE1980
- Alveolar volume-surface area relation in air- and saline-filled lungs fixed by vascular perfusionJournal of Applied Physiology, 1979
- Effect of positive pressure breathing on lung lymph flow and water content in sheep.Circulation Research, 1978
- Cascade impactor design and performanceJournal of Aerosol Science, 1977
- A STUDY OF PARTICULATE CLEARANCE FROM HUMAN LUNGS1967
- Factors affecting bronchial collateral flow in the dogAmerican Journal of Physiology-Legacy Content, 1960
- RESPIRATORY FUNCTION AND BLOOD FLOW IN THE BRONCHIAL ARTERY AFTER LIGATION OF THE PULMONARY ARTERYAmerican Journal of Physiology-Legacy Content, 1949