Reliability of Longitudinal Brain Volume Loss Measurements between 2 Sites in Patients with Multiple Sclerosis: Comparison of 7 Quantification Techniques
Open Access
- 12 July 2012
- journal article
- research article
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 33 (10) , 1918-1924
Abstract
BACKGROUND AND PURPOSE: Brain volume loss is currently a MR imaging marker of neurodegeneration in MS. Available quantification algorithms perform either direct (segmentation-based techniques) or indirect (registration-based techniques) measurements. Because there is no reference standard technique, the assessment of their accuracy and reliability remains a difficult goal. Therefore, the purpose of this work was to assess the robustness of 7 different postprocessing algorithms applied to images acquired from different MR imaging systems. MATERIALS AND METHODS: Nine patients with MS were followed longitudinally over 1 year (3 time points) on two 1.5T MR imaging systems. Brain volume change measures were assessed using 7 segmentation algorithms: a segmentation-classification algorithm, FreeSurfer, BBSI, KN-BSI, SIENA, SIENAX, and JI algorithm. RESULTS: Intersite variability showed that segmentation-based techniques and SIENAX provided large and heterogeneous values of brain volume changes. A Bland-Altman analysis showed a mean difference of 1.8%, 0.07%, and 0.79% between the 2 sites, and a wide length agreement interval of 11.66%, 7.92%, and 11.94% for the segmentation-classification algorithm, FreeSurfer, and SIENAX, respectively. In contrast, registration-based algorithms showed better reproducibility, with a low mean difference of 0.45% for BBSI, KN-BSI and JI, and a mean length agreement interval of 1.55%. If SIENA obtained a lower mean difference of 0.12%, its agreement interval of 3.29% was wider. CONCLUSIONS: If brain atrophy estimation remains an open issue, future investigations of the accuracy and reliability of the brain volume quantification algorithms are needed to measure the slow and small brain volume changes occurring in MS.Keywords
This publication has 50 references indexed in Scilit:
- Evaluation of brain atrophy estimation algorithms using simulated ground-truth dataMedical Image Analysis, 2010
- Robust atrophy rate measurement in Alzheimer's disease using multi-site serial MRI: Tissue-specific intensity normalization and parameter selectionNeuroImage, 2010
- Gradient distortions in MRI: Characterizing and correcting for their effects on SIENA-generated measures of brain volume changeNeuroImage, 2010
- Evaluation of 14 nonlinear deformation algorithms applied to human brain MRI registrationNeuroImage, 2009
- MRI-derived measurements of human subcortical, ventricular and intracranial brain volumes: Reliability effects of scan sessions, acquisition sequences, data analyses, scanner upgrade, scanner vendors and field strengthsNeuroImage, 2009
- Tensor-based morphometry as a neuroimaging biomarker for Alzheimer's disease: An MRI study of 676 AD, MCI, and normal subjectsNeuroImage, 2008
- Accuracy assessment of global and local atrophy measurement techniques with realistic simulated longitudinal Alzheimer's disease imagesNeuroImage, 2008
- Intensity non-uniformity correction using N3 on 3-T scanners with multichannel phased array coilsNeuroImage, 2008
- Detection of cortical thickness correlates of cognitive performance: Reliability across MRI scan sessions, scanners, and field strengthsNeuroImage, 2008
- Voxel-Based Morphometry—The MethodsNeuroImage, 2000