Regional Implementation of Creatinine Measurement Standardization
Authors:
Open Access
- 1 January 2008
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of the American Society of Nephrology
- Vol. 19 (1) , 164-169
Abstract
Because patients may receive care at multiple locations within a geographic area, serum creatinine measurements must be standardized across laboratories to enable comparisons of reported estimated glomerular filtration rate (eGFR). The results of a successful creatinine standardization program designed to minimize the contribution of laboratory error to the reporting of eGFR are reported; 107 laboratories, which tested creatinine on 124 analyzers from six different manufacturers, voluntarily participated. Each laboratory received a correction factor to apply to its creatinine measurements to standardize them to the isotope dilution mass spectrometry reference method. The adjusted values were then used to calculate eGFR using the Modification of Diet in Renal Disease (MDRD) equation. The standardization program reduced the average total error in the measurement of creatinine from 23.9 to 8.7% and the average analytical bias from 16.5 to 2.7%. Implementing this program on a larger scale could reduce the rate of incorrect classification of stage 3 chronic kidney disease by 84%.Keywords
This publication has 9 references indexed in Scilit:
- Using Standardized Serum Creatinine Values in the Modification of Diet in Renal Disease Study Equation for Estimating Glomerular Filtration RateAnnals of Internal Medicine, 2006
- Recommendations for Improving Serum Creatinine Measurement: A Report from the Laboratory Working Group of the National Kidney Disease Education ProgramClinical Chemistry, 2006
- BDNF Acutely Modulates Synaptic Transmission and Calcium Signalling in Developing Cortical NeuronsCellular Physiology and Biochemistry, 2005
- Definition and classification of chronic kidney disease: A position statement from Kidney Disease: Improving Global Outcomes (KDIGO)Kidney International, 2005
- Creatinine measurement: state of the art in accuracy and interlaboratory harmonization.Archives of Pathology & Laboratory Medicine, 2005
- Creatinine Measurement: State of the Art in Accuracy and Interlaboratory HarmonizationArchives of Pathology & Laboratory Medicine, 2005
- Calibration and random variation of the serum creatinine assay as critical elements of using equations to estimate glomerular filtration rateAmerican Journal of Kidney Diseases, 2002
- ForewordAmerican Journal of Kidney Diseases, 2002
- Frozen Human Serum Reference Material for Standardization of Sodium and Potassium Measurements in Serum or Plasma by Ion-Selective Electrode AnalyzersClinical Chemistry, 1992