Abstract
Antibody-based proteomics is an enabling technology that has significant implications for cancer biomarker discovery, diagnostic screening, prognostic and pharmacodynamic evaluation of disease state, and targeted therapeutics. Quantum dot based fluoro-immunoconjugates possess promising features toward realization of this goal such as high photostability, brightness, and multispectral tunability. However, current strategies to generate such conjugates are riddled with complications such as improper orientation of antigen binding sites of the antibody, aggregation, and stability issues. We report a facile yet effective strategy to conjugate anti-epidermal growth factor receptor (EGFR) antibody to quantum dots using copper-free click reaction, and compared them to similar constructs prepared using traditional strategies such as succinimidyl-4-(N-maleimidomethyl) cyclohexane-1-carboxylate (SMCC) and biotin–streptavidin schemes. The Fc and Fab regions of the conjugates retain their binding potential, compared to those generated through the traditional schemes. We further applied the conjugates in testing a novel microsphere array device designed to carry out sensitive detection of cancer biomarkers through fluoroimmunoassays. Using purified EGFR, we determined the limit of detection of the microscopy centric system to be 12.5 ng/mL. The biological assay, in silico, was successfully tested and validated by using tumor cell lysates, as well as human serum from breast cancer patients, and the results were compared to normal serum. A pattern consistent with established clinical data was observed, which further validates the effectiveness of the developed conjugates and its successful implementation both in vitro as well as in silico fluoroimmunoassays. The results suggest the potential development of a high throughput in silico paradigm for predicting the class of patient cancer based on EGFR expression levels relative to normal reference levels in blood.Keywords
This publication has 29 references indexed in Scilit:
- Conjugation of Transferrin to Azide‐Modified CdSe/ZnS Core–Shell Quantum Dots using Cyclooctyne Click ChemistryAngewandte Chemie International Edition, 2012
- Fluorescent-labeled antibodies: Balancing functionality and degree of labelingAnalytical Biochemistry, 2010
- Serum epidermal growth factor receptor and HER2 expression in primary and metastatic breast cancer patientsBreast Cancer Research, 2007
- Cell-based sensor for analysis of EGFR biomarker expression in oral cancerLab on a Chip, 2007
- Serum EGFR and serum HER‐2/neu are useful predictive and prognostic markers in metastatic breast cancer patients treated with metronomic chemotherapyCancer, 2007
- Quantum dot bioconjugates for imaging, labelling and sensingNature Materials, 2005
- Quantum Dots for Live Cells, in Vivo Imaging, and DiagnosticsScience, 2005
- Mechanisms of resistance to Erbitux (anti–epidermal growth factor receptor) combination therapy in pancreatic adenocarcinoma cellsJournal of Gastrointestinal Surgery, 2004
- Assessment of the Effect of Increased Fluorophore Labelling on the Binding Ability of an AntibodyAnalytical Letters, 1996
- Model for the complex between protein G and an antibody Fc fragment in solutionStructure, 1995