A novel echocardiographic hemodynamic index for predicting outcome of aortic stenosis patients following transcatheter aortic valve replacement
Authors:
Open Access
- 26 April 2018
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (4) , e0195641
Abstract
Transcatheter aortic valve replacement (TAVR) reduces left ventricular (LV) afterload and improves prognosis in aortic stenosis (AS) patients. However, LV afterload consists of both valvular and arterial loads, and the benefits of TAVR may be attenuated if the arterial load dominates. We proposed a new hemodynamic index, the Relative Valve Load (RVL), a ratio of mean gradient (MG) and valvuloarterial impedance (Zva), to describe the relative contribution of the valvular load to the global LV load, and examined whether RVL predicted patient outcome following TAVR. A total of 258 patients with symptomatic severe AS (indexed aortic valve area (AVA)2/m2, AR≤2+) underwent successful TAVR at the University of Ottawa Heart Institute and had clinical follow-up to 1-year post-TAVR. Pre-TAVR MG, AVA, percent stroke work loss (%SWL), Zva and RVL were measured by echocardiography. The primary endpoint was all cause mortality at 1-year post TAVR. There were 53 deaths (20.5%) at 1-year. RVL≤7.95ml/m2 had a sensitivity of 60.4% and specificity of 75.1% for identifying all cause mortality at 1-year post-TAVR and provided better specificity than MG0.75cm2, %SWL≤25% and Zva>5mmHg/ml/m2 despite equivalent or better sensitivity. In multivariable Cox analysis, RVL≤7.95ml/m2 was an independent predictor of all cause mortality (HR 3.2, CI 1.8–5.9; p2 was predictive of all cause mortality in both low flow and normal flow severe AS. RVL is a strong predictor of all-cause mortality in severe AS patients undergoing TAVR. A pre-procedural RVL≤7.95ml/m2 identifies AS patients at increased risk of death despite TAVR and may assist with decision making on the benefits of TAVR.Keywords
This publication has 33 references indexed in Scilit:
- Predictors of Mortality and Outcomes of Therapy in Low-Flow Severe Aortic StenosisCirculation, 2013
- Transcatheter versus Surgical Aortic-Valve Replacement in High-Risk PatientsNew England Journal of Medicine, 2011
- Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo SurgeryNew England Journal of Medicine, 2010
- Usefulness of the Valvuloarterial Impedance to Predict Adverse Outcome in Asymptomatic Aortic StenosisJACC, 2009
- Echocardiographic Assessment of Valve Stenosis: EAE/ASE Recommendations for Clinical PracticeJournal of the American Society of Echocardiography, 2009
- Impact of blood pressure on the Doppler echocardiographic assessment of severity of aortic stenosisHeart, 2006
- Response to Letter Regarding Article, “Projected Valve Area at Normal Flow Rate Improves the Assessment of Stenosis Severity in Patients With Low-Flow, Low-Gradient Aortic Stenosis: The Multicenter TOPAS (Truly or Pseudo-Severe Aortic Stenosis) Study”Circulation, 2006
- Projected Valve Area at Normal Flow Rate Improves the Assessment of Stenosis Severity in Patients With Low-Flow, Low-Gradient Aortic StenosisCirculation, 2006
- Reduced Systemic Arterial Compliance Impacts Significantly on Left Ventricular Afterload and Function in Aortic StenosisJACC, 2005
- Impact of systemic hypertension on the assessment of aortic stenosisHeart, 2005