New real-time patient radiation dosimeter for use in radiofrequency catheter ablation
Authors:
Open Access
- 8 January 2019
- journal article
- research article
- Published by Oxford University Press (OUP) in Journal of Radiation Research
- Vol. 60 (2) , 215-220
Abstract
In a previous study, we reported on a novel (prototype) real-time patient dosimeter with non-toxic phosphor sensors. In this study, we developed new types of sensors that were smaller than in the previous prototype, and clarified the clinical feasibility of our newly proposed dosimeter. Patient dose measurements obtained with the newly proposed real-time dosimeter were compared with measurements obtained using a calibrated radiophotoluminescence glass reference dosimeter (RPLD). The reference dosimeters were set at almost the same positions as the new real-time dosimeter sensors. We found excellent correlations between the reference RPLD measurements and those obtained using our new real-time dosimeter (r2 = 0.967). However, the new type of dosimeter was found to underestimate radiation skin dose measurements when compared with an RPLD. The most probable reason for this was the size reduction in the phosphor sensor of the new type of dosimeter. We believe that, as a result of reducing the phosphor sensor size, the backscattered X-ray irradiation was underestimated. However, the new dosimeter can accurately determine the absorbed dose by correcting the measured value with calibration factors. The calibration factor for the new type dosimeter was determined (by linear regression) to be ~1.15. New real-time patient dosimeter design would be an effective tool for the real-time measurement of patient skin doses during interventional radiology treatments.Keywords
Funding Information
- Grant-in-Aid for Scientific Research (16K09029)
- Japan Society for the Promotion of Science
- Radiation Safety Research Promotion Fund
- Nuclear Regulation Authority
This publication has 30 references indexed in Scilit:
- The necessity of follow-up for radiation skin injuries in patients after percutaneous coronary interventions: radiation skin injuries will often be overlooked clinicallyActa Radiologica, 2012
- Quality Improvement Guidelines for Recording Patient Radiation Dose in the Medical Record for Fluoroscopically Guided ProceduresJournal of Vascular and Interventional Radiology, 2012
- Fears, Feelings, and Facts: Interactively Communicating Benefits and Risks of Medical Radiation With PatientsAmerican Journal of Roentgenology, 2011
- Radiation Dose to the Pediatric Cardiac Catheterization and Intervention PatientAmerican Journal of Roentgenology, 2010
- Evaluating the maximum patient radiation dose in cardiac interventional proceduresRadiation Protection Dosimetry, 2010
- Radiation Dose of Interventional Radiology System Using a Flat-Panel DetectorAmerican Journal of Roentgenology, 2009
- Radiation Exposure to Patients During Interventional Procedures in 20 Countries: Initial IAEA Project ResultsAmerican Journal of Roentgenology, 2009
- Relationship Between Fluoroscopic Time, Dose–Area Product, Body Weight, and Maximum Radiation Skin Dose in Cardiac Interventional ProceduresAmerican Journal of Roentgenology, 2006
- Does Digital Acquisition Reduce Patients' Skin Dose in Cardiac Interventional Procedures? An Experimental StudyAmerican Journal of Roentgenology, 2004
- Abstract: Avoidance of radiation injuries from medical interventional procedures, ICRP Publication 85Annals of the ICRP, 2000