X-ray induced Sm3+ to Sm2+ conversion in fluorophosphate and fluoroaluminate glasses for the monitoring of high-doses in microbeam radiation therapy
- 1 October 2012
- journal article
- conference paper
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 112 (7) , 073108
Abstract
Fluorophosphate and fluoroaluminate glasses doped with trivalent samarium were evaluated as sensors of x-ray radiation for microbeam radiation therapy at the Canadian Light Source using the conversion of trivalent Sm3+ to the divalent form Sm2+. Both types of glasses show similar conversion rates and may be used as a linear sensor up to ∼150 Gy and as a nonlinear sensor up to ∼2400 Gy, where saturation is reached. Experiments with a multi-slit collimator show high spatial resolution of the conversion pattern; the pattern was acquired by a confocal fluorescence microscopy technique. The effects of previous x-ray exposure may be erased by annealing at temperatures exceeding the glass transition temperature Tg while annealing at TA < Tg enhances the Sm conversion. This enhancement is explained by a thermally stimulated relaxation of host glass ionic matrix surrounding x-ray induced Sm2+ ions. In addition, some of the Sm3+-doped glasses were codoped with Eu2+-ions but the results show that there is no marked improvement in the conversion efficiency by the introduction of Eu2+.Keywords
This publication has 38 references indexed in Scilit:
- High resolution optical calorimetry for synchrotron microbeam radiation therapyJournal of Instrumentation, 2011
- Development of confocal laser microscope system for examination of microscopic characteristics of radiophotoluminescence glass dosemetersRadiation Protection Dosimetry, 2011
- The thermoluminescence response of Ge-doped silica fibres for synchrotron microbeam radiation therapy dosimetryNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2010
- Tumor Cell Response to Synchrotron Microbeam Radiation Therapy Differs Markedly From Cells in Normal TissuesInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2010
- Potential High Resolution Dosimeters For MRTAIP Conference Proceedings, 2010
- New technology enables high precision multislit collimators for microbeam radiation therapyReview of Scientific Instruments, 2009
- Microbeam radiation therapy: Tissue dose penetration and BANG-gel dosimetry of thick-beams’ array interlacingEuropean Journal of Radiology, 2008
- Dosimetry for a microbeam array generated by synchrotron radiation at SPring-8European Journal of Radiology, 2008
- Microbeam radiation therapy1999
- Microbeam radiation therapyMedical Physics, 1992