A Multi-filter and Multi-scale U-Net for Cone-Beam Computed Tomography
Open Access
- 17 June 2026
- book chapter
- Published by Springer Nature
- p. 3-18
Abstract
Efficient 3D cone-beam computed tomography (CBCT) reconstructions typically demand substantial hardware capabilities for both training and execution. This paper introduces a multi-filter and multi-scale U-Net (mU-Net) architecture designed for post-processing CBCT images by incorporating multiple input channels, each processed with distinct frequency filters or reconstruction resolutions. We present a detailed comparison between the mU-Net and a baseline U-Net for low-dose and clinical dose denoising scenarios, reporting key metrics such as Peak Signal-to-Noise Ratio (PSNR), Structural Similarity Index Measure (SSIM), and inference time. The mU-Net showed only marginal quantitative differences compared with the baseline U-Net: it performed slightly better in the clinical dose scenario, while the baseline U-Net performed better in the low-dose scenario. The mU-Net required approximately 13% more time per epoch during training and 13.08 s per volume for FDK reconstruction and inference, compared with 10.43 s per volume for the baseline U-Net. In the clinical dose scenario, the mU-Net showed slightly improved visual noise texture and artifact suppression, but these observations were not supported by dedicated texture or observer-study metrics. Notably, the mU-Net and baseline U-Net approaches placed 3rd in the ICASSP 2024 3D-CBCT grand challenge, demonstrating that a properly trained U-Net remains competitive. This study shows that multi-filter and multi-scale inputs can be used for CBCT post-processing under limited computational resources, but the gains over a baseline U-Net were modest.Keywords
This publication has 17 references indexed in Scilit:
- Deep learning enables time-efficient soft tissue enhancement in CBCT: Proof-of-concept study for dentomaxillofacial applicationsPhysica Medica, 2023
- Dental cone beam CT: An updated reviewPhysica Medica, 2021
- Performance evaluation of computed tomography systems: Summary of AAPM Task Group 233Medical Physics, 2019
- Clinical Brachytherapy Physics. AAPM Medical Physics Monograph No. 38. Editors: MJRivard, LBeaulieu & BRThomadsen. Madison, Wisconsin: Medical Physics Publishing Inc., 2017. Hardcover 372 pp. Price: $110.00. ISBN 978-1936366576.Medical Physics, 2018
- 3D U-Net: Learning Dense Volumetric Segmentation from Sparse Annotation2016
- Image quality in CT: From physical measurements to model observersPhysica Medica, 2015
- U-Net: Convolutional Networks for Biomedical Image Segmentation2015
- The ASTRA Toolbox: A platform for advanced algorithm development in electron tomographyUltramicroscopy, 2015
- Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimizationPhysics in Medicine & Biology, 2008
- Handbook of Medical Imaging. Volumes 1-3Physics Today, 2001