Evaluation of a cochlear-implant processing strategy incorporating phantom stimulation and asymmetric pulses
Authors:
- Robert P. CarlyonRCRobert P. Carlyon
- Jolijn MonstreyJMJolijn Monstrey
- John M. DeeksJDJohn M. Deeks
- Olivier MachereyOMOlivier Macherey
Open Access
- 7 July 2014
- journal article
- research article
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 53 (12) , 871-879
Abstract
To evaluate a speech-processing strategy in which the lowest frequency channel is conveyed using an asymmetric pulse shape and "phantom stimulation", where current is injected into one intra-cochlear electrode and where the return current is shared between an intra-cochlear and an extra-cochlear electrode. This strategy is expected to provide more selective excitation of the cochlear apex, compared to a standard strategy where the lowest-frequency channel is conveyed by symmetric pulses in monopolar mode. In both strategies all other channels were conveyed by monopolar stimulation. Within-subjects comparison between the two strategies. Four experiments: (1) discrimination between the strategies, controlling for loudness differences, (2) consonant identification, (3) recognition of lowpass-filtered sentences in quiet, (4) sentence recognition in the presence of a competing speaker. Eight users of the Advanced Bionics CII/Hi-Res 90k cochlear implant. Listeners could easily discriminate between the two strategies but no consistent differences in performance were observed. The proposed method does not improve speech perception, at least in the short term.Keywords
This publication has 20 references indexed in Scilit:
- Place-pitch manipulations with cochlear implantsThe Journal of the Acoustical Society of America, 2012
- Extending the Limits of Place and Temporal Pitch Perception in Cochlear Implant UsersJournal of the Association for Research in Otolaryngology, 2010
- Use of “Phantom Electrode” Technique to Extend the Range of Pitches Available Through a Cochlear ImplantEar & Hearing, 2010
- The upper limit of temporal pitch for cochlear-implant listeners: Stimulus duration, conditioner pulses, and the number of electrodes stimulatedThe Journal of the Acoustical Society of America, 2010
- Forward-masking patterns produced by symmetric and asymmetric pulse shapes in electric hearingThe Journal of the Acoustical Society of America, 2010
- Higher Sensitivity of Human Auditory Nerve Fibers to Positive Electrical CurrentsJournal of the Association for Research in Otolaryngology, 2008
- HiResolutionTM and Conventional Sound Processing in the HiResolutionTM Bionic Ear: Using Appropriate Outcome Measures to Assess Speech Recognition AbilityAudiology and Neurotology, 2004
- Loudness perception with pulsatile electrical stimulation: The effect of interpulse intervalsThe Journal of the Acoustical Society of America, 1998
- Performance over time of adult patients using the Ineraid or Nucleus cochlear implantThe Journal of the Acoustical Society of America, 1997
- An Analysis of Perceptual Confusions Among Some English ConsonantsThe Journal of the Acoustical Society of America, 1955