All-Solid-State Separated Potassium Electrode Based on SnO[sub 2]/ITO Glass
Authors:
- 1 January 2007
- journal article
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 154 (11) , J369-J374
Abstract
An all-solid-state potassium electrode based on tin oxide (SnO2)(SnO2) /indium tin oxide (ITO) glass is developed in this paper. The sensing membrane of the electrode is prepared by mixing poly(vinyl chloride) (PVC), bis(2-ethylhexyl) sebacate (DOS), valinomycin (VAL), and potassium tetrakis(p-chlorophenyl) borate (KTpClPB). The mixed solution is dissolved in tetrahydrofuran (THF). Then, it is dropped on the sensing window of SnO2SnO2 /ITO glass. In addition, the Ag∕AgClAg∕AgCl wire, which is coated PVC membrane containing 3.5MKCl3.5MKCl powder, is used as a miniaturized reference electrode in this study. The optimum experiment of the potassium sensor is conducted by observing the characteristics of sensitivity and selectivity in different weight ratios. After the optimum experimental trials, the best weight ratio of the potassium sensor is PVC:DOS:VAL:KTpClPB = 33:66:4:2. In this optimum condition, the sensitivity is 56.4mV56.4mV /decade with linear concentration range between 1×10−5M1×10−5M and 1M1M . The low detection limit of the sensor reaches to 8×10−6M8×10−6M , and response time is <1s<1s . Moreover, the sensor is slight interfered by sodium, calcium, and magnesium ions. The pH variation does not affect its electromotive force in the range between pH 6 and pH 12. The sensor possesses reusable properties showing that it can be repeated, measuring 30 times.Keywords
This publication has 34 references indexed in Scilit:
- Fundamental studies on SnO2 by means of simultaneous work function change and conduction measurementsThin Solid Films, 2005
- Analytical features of K+-sensitive membrane obtained by implantation in silicon dioxide filmsMaterials Science and Engineering: C, 2002
- Improved potassium-selective membrane using valinomycin as ionophore for ion-selective microdevicesMaterials Science and Engineering: C, 2001
- Work function measurements on indium tin oxide filmsJournal of Electron Spectroscopy and Related Phenomena, 2001
- Assessing a photocured self-plasticised acrylic membrane recipe for Na+ and K+ ion selective electrodesAnalytica Chimica Acta, 2001
- Work function changes and surface chemistry of oxygen, hydrogen, and carbon on indium tin oxideApplied Surface Science, 2001
- Potassium-selective conductometric sensorSensors and Actuators B: Chemical, 2001
- Study on extended gate field effect transistor with tin oxide sensing membraneMaterials Chemistry and Physics, 2000
- Plasticizer-free all-solid-state potassium-selective electrode based on poly(3-octylthiophene) and valinomycinAnalytica Chimica Acta, 1999
- A potassium-ion selective electrode with valinomycin based poly(vinyl chloride) membrane and a poly(vinyl ferrocene) solid contactAnalytica Chimica Acta, 1995