CVD diamond as a high bandwidth neutron detector for inertial confinement fusion diagnostics
Authors:
- 1 March 2003
- journal article
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 74 (3) , 1828-1831
Abstract
We characterize the response of chemical vapor deposition(CVD)diamonddetectors to inertial confinement fusion(ICF)neutrons generated at the OMEGA laser fusion facility in Rochester, NY. Four detectors are tested: three utilizing “optical grade” CVDdiamond, and one utilizing “electronic grade” CVDdiamond. Using a 50 Ω measurement system, we find that the optical grade wafers, biased to 1000 V/mm, have an average sensitivity of 0.24 μV ns/n for 2.5 MeV (DD fusion) neutrons and 0.62 μV ns/n for 14.0 MeV (DT fusion) neutrons. At the same E field, the electronic grade wafer has a sensitivity of 0.56 and 1.43 μV ns/n for 2.5 and 14 MeV neutrons, respectively. Linear dynamic range for the optical grade material is shown to be at least 10 5 . Average full width at half maximum response times, as measured with pulsed laser and 3 GHz scope, are 376 and 880 ps for optical and electronic grades, respectively. These characteristics make CVDdiamond suitable for ICF applications such as neutron time-of-flight spectroscopy, bang time measurements, and ion temperature measurements.Keywords
This publication has 11 references indexed in Scilit:
- Scattered and (n,2n) neutrons as a measure of areal density in ICF capsulesNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2002
- CVD diamond detectors for current mode neutron time-of-flight spectroscopy at OMEGA/NIF2001
- Development of lower-energy neutron spectroscopy for areal density measurement in implosion experiment at NIF and OMEGA2001
- The use of CVD-diamond for heavy-ion detectionDiamond and Related Materials, 2001
- Pulse height distribution and radiation tolerance of CVD diamond detectorsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2000
- Target diagnostic system for the national ignition facility (invited)Review of Scientific Instruments, 1997
- New developments in photoconductive detectors (invited)Review of Scientific Instruments, 1997
- 14 MeV neutron spectra measurements with 4% energy resolution using a type IIa diamond detectorNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 1995
- Radiation-induced conductivity: High-speed detection of X rays and neutronsLaser and Particle Beams, 1991
- Absolute x-ray power measurements with subnanosecond time resolution using type IIa diamond photoconductorsJournal of Applied Physics, 1990