Abstract
Introduction: Although three-dimensional marker-based motion analysis is the gold standard for biomechanical investigations, it is time-consuming and cost-intensive. The conjunction of monocular video recordings with pose estimation algorithms addresses this gap. With the Orthelligent VISION app (OPED GmbH) a commercial and easy-to-use tool is now available for implementation in everyday clinical practice. The study investigates the accuracy of the 2D video-based system in measuring joint kinematics, expressed as range of motion, compared to an optoelectronic 3D motion analysis system as the gold standard. Materials and methods: Its accuracy was determined by synchronously measuring ten healthy subjects with Orthelligent and the optoelectronic 3D motion analysis system Qualisys (Qualisys AB) during level walking and at different treadmill walking speeds (1 m/s; 1.4 m/s; 1.8 m/s). Range of motion (RoM) of lower limb joints and time-distance parameters were compared using Bland-Altman plots, t-tests, and correlations between systems. Kinematic outputs of two subjects with a lower limb amputation were also analyzed. Results: The mean RoM deviation was smaller for the knee (3.8°) and hip joints (3.7°) than for the ankle joint (5.4°), but differed significantly between systems in most conditions. The correlation range was 0.36 ≤ r ≤ 0.83, with best results for 1 m/s treadmill walking (mean r = 0.71 across joints). While the accuracy was affected by high inter-subject variability, individual RoM changes from slow to fast walking did not differ between the systems. The kinematics of the prosthetic and sound leg of individuals with an amputation exhibited characteristic patterns in the video-based system, even though side differences were smaller compared to the optoelectronic measurement. Conclusions: The rather high inter-subject variability would make future comparisons between individuals challenging. Nonetheless, the app shows potential for intra-subject progress monitoring.Keywords
This publication has 42 references indexed in Scilit:
- Automatic two-dimensional & three-dimensional video analysis with deep learning for movement disorders: A systematic reviewArtificial Intelligence in Medicine, 2024
- Markerless versus marker-based motion analysis in subjects with lower limb amputation: A case seriesGait & Posture, 2022
- Sampling rate influences the regularity analysis of temporal domain measures of walking more than spatial domain measuresGait & Posture, 2021
- Relationship Between Transverse-plane Kinematic Deviations of Lower Limbs and Gait Performance in Children with Unilateral Cerebral Palsy: A Descriptive AnalysisGait & Posture, 2020
- Evaluation of Clinical Gait Analysis parameters in patients affected by Multiple Sclerosis: Analysis of kinematicsClinical Biomechanics, 2017
- Knee Kinematic and Clinical Outcomes Evolution Before, 3 Months, and 1 Year After Total Knee ArthroplastyThe Journal of Arthroplasty, 2017
- Biomechanics and physiological parameters during gait in lower-limb amputees: A systematic reviewGait & Posture, 2011
- Two simple methods for determining gait events during treadmill and overground walking using kinematic dataGait & Posture, 2008
- Kinematics of the transition between walking and running when gradually changing speedGait & Posture, 2007
- Measurement of lower extremity kinematics during level walkingJournal of Orthopaedic Research, 1990