X‐ray production as a function of depth for low electron energies
Authors:
- 1 January 1976
- journal article
- research article
- Published by Wiley in X-Ray Spectrometry
- Vol. 5 (1) , 36-40
Abstract
Depth distributions of X‐ray production by electrons in the energy range of six to fifteen key have been measured for Si and Cu characteristic X‐rays in matrices of Al, Ni, Ag and Au. Corrections from these curves show that the modified Philibert absorption correction predicts the wrong dependence on matrix atomic number at these low electron energies, while the Duncomb and Reed atomic number correction shows too strong a dependence on atomic number. The curves should be valuable for comparison with both theoretical and empirical models for quantitative analysis at low energies.Keywords
This publication has 5 references indexed in Scilit:
- Absorption Correction Curves Obtained from Measurements of the Production of X-Rays as a Function of Depth1973
- Common Sources of Error in Electron Probe Microanalysis1968
- A Method for Calculating the Absorption Correction in Electron-Probe Microanalysis1963
- Electron Probe Microanalysis1960
- Sur les bases physiques de l'analyse ponctuelle par spectrographie XJournal de Physique et le Radium, 1955