Prediction of In Vivo Knee Joint Kinematics Using a Combined Dual Fluoroscopy Imaging and Statistical Shape Modeling Technique
- 30 October 2014
- journal article
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 136 (12) , 124503-1245036
Abstract
Using computed tomography (CT) or magnetic resonance (MR) images to construct 3D knee models has been widely used in biomedical engineering research. Statistical shape modeling (SSM) method is an alternative way to provide a fast, cost-efficient, and subject-specific knee modeling technique. This study was aimed to evaluate the feasibility of using a combined dual-fluoroscopic imaging system (DFIS) and SSM method to investigate in vivo knee kinematics. Three subjects were studied during a treadmill walking. The data were compared with the kinematics obtained using a CT-based modeling technique. Geometric root-mean-square (RMS) errors between the knee models constructed using the SSM and CT-based modeling techniques were 1.16 mm and 1.40 mm for the femur and tibia, respectively. For the kinematics of the knee during the treadmill gait, the SSM model can predict the knee kinematics with RMS errors within 3.3 deg for rotation and within 2.4 mm for translation throughout the stance phase of the gait cycle compared with those obtained using the CT-based knee models. The data indicated that the combined DFIS and SSM technique could be used for quick evaluation of knee joint kinematics.Keywords
This publication has 30 references indexed in Scilit:
- A statistical finite element model of the knee accounting for shape and alignment variabilityMedical Engineering & Physics, 2013
- Construction of 3D human distal femoral surface models using a 3D statistical deformable modelJournal of Biomechanics, 2011
- Comments on “validation of a non-invasive fluoroscopic imaging technique for the measurement of dynamic knee joint motion”Journal of Biomechanics, 2008
- Predicting the shapes of bones at a joint: application to the shoulderComputer Methods in Biomechanics and Biomedical Engineering, 2008
- Validation of a non-invasive fluoroscopic imaging technique for the measurement of dynamic knee joint motionJournal of Biomechanics, 2008
- The 6 Degrees of Freedom Kinematics of the Knee after Anterior Cruciate Ligament DeficiencyThe American Journal of Sports Medicine, 2006
- In vivo tibiofemoral contact analysis using 3D MRI-based knee modelsJournal of Biomechanics, 2004
- A Biplanar Reconstruction Method Based on 2D and 3D Contours: Application to the Distal FemurComputer Methods in Biomechanics and Biomedical Engineering, 2003
- Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopyIEEE Transactions on Biomedical Engineering, 1996
- Seeded region growingIEEE Transactions on Pattern Analysis and Machine Intelligence, 1994