Longer storage of dialyzers increases elution of poly(N-vinyl-2-pyrrolidone) from polysulfone-group dialysis membranes
- 2 February 2011
- journal article
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 14 (1) , 52-57
Abstract
The objective of this study was to evaluate the effect of protracted storage of dialyzers on the amount of poly(N-vinyl-2-pyrrolidone) (PVP) eluted from polysulfone-group dialysis membranes. We tested five dialysis membranes: APS-15SA (Asahi Kasei Kuraray, wet), CX-1.6U (Toray, moist), FX140 (Fresenius, dry), PES-15Sα (Nipro, dry), and FDX-150GW (Nikkiso, wet). Each dialyzer was stored for 1, 3, 14, and 18 months after sterilization. The dialysis-fluid side compartment was primed with reverse osmosis (RO) water at 500 mL/min for 5 min at 310 K. The blood side compartment was primed with RO water at 200 mL/min for 5 min at 310 K. Finally, 1 L RO water was circulated through the blood side compartment at 200 mL/min for 4 h at 310 K. Eluted PVP was determined by use of the iodine method, using 0.02 N iodine solution. PVP was mainly eluted from wet-type dialyzers during priming. Thus, the standard 5 min priming of the wet-type dialyzer according to the maker manual inhibits PVP elution during circulation. PVP was eluted in the dialysis-fluid side of the moist-type dialyzer during priming but no PVP was eluted in the blood side. PVP was mainly eluted from dry-type dialyzers during circulation. We recommend more than the standard 5 min priming, particularly for dry-type dialyzers stored for protracted periods, because 5 min insufficient to inhibit PVP elution during circulation.Keywords
This publication has 15 references indexed in Scilit:
- Photooxidation of poly(N-vinylpyrrolidone) (PVP) in the solid state and in aqueous solutionPolymer Degradation and Stability, 2009
- Nanotechnological Characterization of Human Serum Albumin Adsorption on Wet Synthetic Polymer Dialysis Membrane SurfacesASAIO Journal, 2009
- Nanotechnological evaluation of protein adsorption on dialysis membrane surface hydrophilized with polyvinylpyrrolidoneJournal of Membrane Science, 2008
- How polysulfone dialysis membranes containing polyvinylpyrrolidone achieve excellent biocompatibility?Journal of Membrane Science, 2004
- Nanoscopic behavior of polyvinylpyrrolidone particles on polysulfone/polyvinylpyrrolidone filmBiomaterials, 2004
- Pore size distributions based on AFM imaging and retention of multidisperse polymer solutesJournal of Membrane Science, 2001
- Polymerization of N-Vinyl-2-Pyrrolidone under Anodic Polarization: Characterization of the Modified Electrode and Study of the Grafting MechanismLangmuir, 1997
- POLYSULPHONE MEMBRANE MIMICKING HUMAN GLOMERULAR BASEMENT MEMBRANEThe Lancet, 1983
- γ-Irradiation of N-vinylpyrrolidin-2-one and its homopolymerAustralian Journal of Chemistry, 1981
- The lactam‐amino acid equilibria for ethylpyrrolidone and polyvinylpyrrolidoneJournal of Polymer Science, 1954