Robot‐assisted laparoscopic artificial urinary sphincter insertion in women with stress urinary incontinence: a pilot single‐centre study
- 19 June 2020
- journal article
- research article
- Published by Wiley in BJU International
- Vol. 126 (6) , 722-730
Abstract
Objective To report the functional outcomes of robot‐assisted laparoscopic artificial urinary sphincter (AUS, AMS 800TM) implantation and revision in women with stress urinary incontinence. Materials and methods A pilot prospective monocentric study included all consecutive female patients suffering from stress urinary incontinence and undergoing an AUS surgery (implantation or revision) using a robotic approach between 2012 and 2018. The AUS was implanted through a transperitoneal robotic approach. The dissection of the bladder neck was initiated using a posterior approach with a permanent visual control. Intra and early postoperative complications were reported (Clavien’s classification). Continence was defined as no pad usage. Results A total of 41 patients, median age 67.5 years (IQR 57‐74.7) were included. In the group of 27 patients undergoing an AUS implantation, one conversion to laparotomy, one bladder neck and one ureteral injury occurred. The AUS was not implanted in the 2 latest cases. Twelve minor (Clavien I‐II) early postoperative complications occurring in 10 patients were reported. The median follow‐up was 19 months (IQR 11‐27). The continence rate was 84% (21/25 patients). In the group of 14 patients undergoing an AUS revision, no vaginal or bladder injury was reported. One patient had a bowel injury with conversion to laparotomy without AUS implantation. Two major (III‐V) early postoperative complications occurred in 2 patients: one intraoperative bowel injury, which ultimately resulted in the death of the patient and one device infection requiring an explantation of the AUS. The median follow‐up was 18 months (IQR 13.5‐24.2). The continence rate was 83.3% (10/12 patients). Conclusion The results obtained after robot‐assisted laparoscopic AUS implantation among women are promising despite the significant morbidity due to previous pelvic surgeries. Longer follow‐up studies are needed.Keywords
This publication has 20 references indexed in Scilit:
- Robotic-assisted Laparoscopic Implantation of Artificial Urinary Sphincter in Women With Intrinsic Sphincter Deficiency Incontinence: Initial ResultsUrology, 2014
- Long‐term functional outcomes after artificial urinary sphincter implantation in women with stress urinary incontinenceBJU International, 2014
- Reporting and Grading of Complications After Urologic Surgical Procedures: An ad hoc EAU Guidelines Panel Assessment and RecommendationsEuropean Urology, 2012
- Laparoscopic Surgical Complete Sling Resection for Tension-Free Vaginal Tape–Related Complications Refractory to First-Line Conservative Management: A Single-Centre ExperienceEuropean Urology, 2010
- Laparoscopic artificial urinary sphincter implantation for female genuine stress urinary incontinence: technique and 4‐year experience in 25 patientsBJU International, 2010
- Repeat Synthetic Mid Urethral Sling Procedure for Women With Recurrent Stress Urinary IncontinenceJournal of Urology, 2010
- Outcomes Following Repeat Mid Urethral Synthetic Sling After Failure of the Initial Sling Procedure: Rediscovery of the Tension-Free Vaginal Tape ProcedureJournal of Urology, 2007
- Laparoscopic Artificial Urinary Sphincter in Women for Type III Incontinence: Preliminary ResultsEuropean Urology, 2005
- THE USE OF AN ARTIFICIAL URINARY SPHINCTER IN WOMEN WITH TYPE III INCONTINENCE AND A NEGATIVE MARSHALL TESTJournal of Urology, 2001
- Techniques and results in the implantation of the artificial urinary sphincter in women with type III stress urinary incontinence by a vaginal approachNeurourology and Urodynamics, 1988