Avoiding end hits in ultrasound-assisted lipoplasty
Author:
Open Access
- 1 September 1997
- journal article
- Published by Oxford University Press (OUP) in Aesthetic Surgery Journal
- Vol. 17 (5) , 331-333
Abstract
A potential disadvantage of ultrasound-assisted lipoplasty is tissue burns. These may occur when the tip of the probe hits the undersurface of the skin. These “end hits” occur when the tip of the probe is vertically oriented to the skin surface, and they are more likely to happen when the surgeon is trying to go around the sides of the patient from centrally located access incisions. To help avoid hitting the skin's undersurface around the lateral aspect of an area being treated, a lateral meridian is drawn before surgery with the patient standing (Figure 1). The surgeon should not cross this lateral meridian when working in an anterior direction from the central access incisions with the patient in a prone position or when working in a posterior direction with the patient in a supine position. The prone position (Figure 2) displaces this lateral line posteriorly, whereas the supine position (Figure 3) displaces it anteriorly because the operating room table pushes against the patient's body.Keywords
This publication has 4 references indexed in Scilit:
- Subcutaneous Approach To Forehead, Brow, And Modified Temple IncisionClinics in Plastic Surgery, 1992
- A Method of Direct Eyebrow LiftAnnals of Plastic Surgery, 1983
- Midforehead Incisions in Treatment of the Aging FaceJAMA Otolaryngology–Head & Neck Surgery, 1982
- The Anatomy of Eyebrow PtosisArchives of Ophthalmology (1950), 1982