Promoting Patient-Ventilator Synchrony
- 1 November 2007
- journal article
- research article
- Published by Wolters Kluwer Health in Clinical Pulmonary Medicine
- Vol. 14 (6) , 350-359
Abstract
Patient-ventilator asynchrony, in which the patient's inspiration fails to coincide exactly with the ventilator's insufflation, is common in clinical practice. Studies suggest that nearly one-fourth of intubated patients exhibit frequent asynchrony during assisted ventilation. Frequent asynchrony is associated with longer duration of mechanical ventilation, because it may reflect not only greater disease severity, but also inappropriate ventilator settings. New-generation ventilators with large screens facilitate the detection of gross asynchronies by careful examination of flow and airway-pressure tracings. The main asynchrony is ineffective triggering, defined as failure of a patient's inspiratory effort to trigger a ventilator breath. Ineffective triggering is caused by dynamic hyperinflation at the time of a triggering attempt. Other major asynchronies include double triggering, in which 2 consecutive ventilator cycles are triggered by a single patient effort; and auto-triggering, in which the ventilator is triggered by signals that do not come from the patient. More discreet asynchronies such as prolonged insufflation during pressure-support ventilation or inadequate flow rate during assist-control ventilation can also be suspected from the flow and airway-pressure traces. Simple delays in triggering or cycling are extremely common but difficult to detect. Optimizing the ventilator settings, most notably by reducing ventilatory support or insufflation time, can minimize ineffective triggering. New ventilatory modes such as proportional-assist ventilation and neurally adjusted ventilatory assist may improve patient-ventilator synchrony. Whether optimizing ventilation shortens the duration of mechanical ventilation by reducing the occurrence of asynchrony is still an open question.Keywords
This publication has 45 references indexed in Scilit:
- Patient-ventilator asynchrony during assisted mechanical ventilationIntensive Care Medicine, 2006
- Bedside waveforms interpretation as a tool to identify patient-ventilator asynchroniesIntensive Care Medicine, 2005
- Patient–ventilator interactionBritish Journal of Anaesthesia, 2003
- Bench testing of pressure support ventilation with three different generations of ventilatorsIntensive Care Medicine, 2002
- Response of Ventilator-Dependent Patients to Delayed Opening of Exhalation ValveAmerican Journal of Respiratory and Critical Care Medicine, 2002
- Electrical Activity of the Diaphragm during Pressure Support Ventilation in Acute Respiratory FailureAmerican Journal of Respiratory and Critical Care Medicine, 2001
- Patient–Ventilator InteractionAmerican Journal of Respiratory and Critical Care Medicine, 2001
- Patient-ventilator asynchronyCurrent Opinion in Critical Care, 2001
- Cycling of Inspiratory and Expiratory Muscle Groups with the Ventilator in Airflow LimitationAmerican Journal of Respiratory and Critical Care Medicine, 1998
- Patient-Ventilator Trigger Asynchrony in Prolonged Mechanical VentilationChest, 1997