Quasi-Peak-to-RMS Voltage Conversion
Author:
- 1 February 1979
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. EMC-21 (1) , 9-12
Abstract
A technique is presented by which the conversion between quasi-peak and rms voltage levels may be made for any noise process for which the relative amplitude probability distribution is known. The technique is not exact, since it requires that the time waveform of the quasi-peak voltage be constant. However, the resulting error seems to be smail for many cases. Several results obtained using the techniques are given and compared with measurements. An analysis is also presented of the effect of the constant quasi-peak voltage requirement on the error.Keywords
This publication has 4 references indexed in Scilit:
- Radio Noise Meter Response to Random Pulses by Computer SimulationIEEE Transactions on Power Apparatus and Systems, 1974
- Instrumentation Problems Encountered Making Man-Made Electromagnetic Noise Measurements for Predicting Communication System PerformanceIEEE Transactions on Electromagnetic Compatibility, 1970
- Response of Quasi-Peak Detector to Periodic Impulses with Random AmplitudesIEEE Transactions on Electromagnetic Compatibility, 1967
- Response of ideal radio noise meter to continuous sine wave, recurrent impulses, and random noiseIRE Transactions on Radio Frequency Interference, 1961