Full-Scale Testing of CFRP-Strengthened Slender Reinforced Concrete Columns
- 1 April 2013
- journal article
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 17 (2) , 239-248
Abstract
The paper presents an investigation into the performance of slender rectangular reinforced concrete columns strengthened with carbon fiber-reinforced polymers (CFRPs) in two manners. The first approach is a well-known form of CFRP sheet jacketing with the effect demonstrated in many studies, and a second one is a relatively new retrofit method of near surface mounted (NSM) CFRP strips. A total of eight full-scale specimens with rectangular cross sections (210×150 mm) were tested to failure under eccentric compressive loading. The total length of the specimens was 4,100 mm. The results of this study demonstrate a significant difference in slender and short column strengthening in accordance with the predominant stress manner. It was confirmed that the effect of CFRP wraps on the increase in column strength is proportionally greater for short RC columns subjected to predominant compression. The longitudinal fibers in CFRP strips bonded into grooves in concrete cover are more effective in enhancing ...Keywords
This publication has 8 references indexed in Scilit:
- Slenderness Effects on Circular CFRP Confined Reinforced Concrete ColumnsJournal of Composites for Construction, 2010
- Near surface mounted CFRP strips for the flexural strengthening of RC columns: Experimental and numerical researchEngineering Structures, 2008
- Behaviour of CFRP-strengthened slender square RC columnsMagazine of Concrete Research, 2008
- Strengthening and rehabilitation of civil infrastructures using fibre-reinforced polymer (FRP) composites2008
- Experimental investigation of load carrying capacity of the slender reinforced concrete columns wrapped with FRPConstruction and Building Materials, 2007
- Stability of round concrete columns confined by composite wrappingsMechanics of Composite Materials, 2007
- Behaviour of fire-exposed concrete-filled steel tubular beam columns repaired with CFRP wrapsThin-Walled Structures, 2007
- Slenderness Limit for Hybrid FRP-Concrete ColumnsJournal of Composites for Construction, 2001