Diagnostic accuracy cohort study and clinical value of the Histoplasma urine antigen (ALPHA Histoplasma EIA) for disseminated histoplasmosis among HIV infected patients: A multicenter study

Authors:

Abstract
The Histoplasma urine antigen (HUAg) is the preferred method to diagnose progressive disseminated histoplasmosis (PDH) in HIV patients. In 2007, IMMY ALPHA Histoplasma EIA was approved for clinical for on-site use, and therefore useful for regions outside the United States. However, ALPHA-HUAg is considered inferior to the MVista-HUAg which is only available on referral. We aim to evaluate the diagnostic accuracy of ALPHA-HUAg. We conducted a multicenter, prospective, diagnostic test study in two secondary and eight tertiary-care facilities in Mexico. We included HIV patient with PDH suspicion and evaluated ALPHA-HUAg diagnostic accuracy using as reference standard the Histoplasma capsulatum growth on blood, bone marrow, and tissue cultures or compatible histopathologic exam (PDH–proven). We evaluated the results of 288 patients, 29.5% (85/288; 95% confidence interval [CI], 24.3–35.1) had PDH. The sensitivity of ALPHA-HUAg was 67.1% (95% CI, 56–76.8%) and the specificity was 97.5% (95% CI, 94.3%-99.1%). The positive likelihood ratio was 27.2 (95% CI; 11.6–74.4). In 10.5% of the PDH–proven patients, a co-existing opportunistic infection was diagnosed, mostly disseminated Mycobacterium avium complex infection. We observed a high specificity but low sensitivity of IMMY-HUAg. The test may be useful to start early antifungals, but a culture-based approach is necessary since co-infections are frequent and a negative IMMY-HUAg result does not rule out PDH. Histoplasmosis is an endemic mycosis in many regions of Latin America. In the HIV population it manifests as progressive disseminated histoplasmosis (PDH), an entity hard to diagnose since the causative fungi—Histoplasma capsulatum—is slow growing and requires advance biosafety for its handling. As an alternative, the diagnosis can be made by detecting the histoplasma urinary antigen, but only one kit is commercially available outside the US. We evaluated this kit (IMMY ALPHA Histoplasma EIA) among HIV patients with suspected and found a high specificity but low sensitivity (i.e., a positive histoplasma urine antigen is almost unequivocal, but a negative result does not rule out the PDH). However, we believe the test is useful since the positive likelihood rates show that a patient with PDH is 27 times more likely to have an IMMY-HUAg positive result; this may allow early targeted treatment.
Funding Information
  • Secretaría de Ciencia, Humanidades, Tecnología e Innovación (FOSISS 2015-1 261482)

This publication has 25 references indexed in Scilit: