Osteointegration of a modular metal-polyethylene surface gliding finger implant: a case report
- 23 July 2016
- journal article
- case report
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 136 (9) , 1331-1335
Abstract
Introduction Primary press fit and secondary osteointegration is a precondition for component anchoring in articular surface replacements, also in the case of proximal interphalangeal (PIP) joint. Nevertheless, many existing prostheses for the PIP joint have failed to show sufficient osteointegration. CapFlex-PIP© implant is a modular metal-polyethylene surface replacement for the PIP joint consisting of a proximal and distal component each having a titanium pore backside, which allows secondary osteointegration at the bone-implant interface. To evaluate osseous integration of this implant, we report a histological analysis of an explantation of a CapFlex-PIP© finger implant. Case presentation We present a case of a removed CapFlex-PIP© implant due to a soft tissue complication in an 84-year-old woman. The patient received bisphosphonate medication as treatment for osteoporosis. For the histological analysis, the bone-implant contact (BIC) was measured on all stained sections using a Zeiss Axioplan microscope. The summated BIC was 40.7 % for the proximal component and 46.5 % for the distal component of the implant. Histology showed that the implant was in direct contact with the bone at various locations, with no signs of wear or degradation. Conclusions This case demonstrates successful osteointegration of the CapFlex-PIP© implant. Both components of the investigated implant show osseous integration to an extent which is comparable to that of other load-bearing and articulating implants at different locations in the human body.Keywords
Funding Information
- KLS Martin Group, Tuttlingen, Germany
This publication has 19 references indexed in Scilit:
- Increased migration of uncemented acetabular cups in female total hip arthroplasty patients with low systemic bone mineral densityActa Orthopaedica, 2015
- Biomaterial strategies for engineering implants for enhanced osseointegration and bone repairAdvanced Drug Delivery Reviews, 2015
- Impact of osteoporosis in dental implants: A systematic reviewWorld Journal of Orthopedics, 2015
- Insertion of the Ascension PyroCarbon PIP total joint in 152 human cadaver fingers: analysis of implant positions and malpositionsArchives of orthopaedic and trauma surgery, 2014
- Ten year follow-up of pyrocarbon implants for proximal interphalangeal joint replacementJournal of Hand Surgery (European Volume), 2014
- Mid-term results of a metal-backed glenoid component in total shoulder replacementThe Journal of Bone and Joint Surgery. British volume, 2010
- Osseointegration of zirconia and titanium dental implants: a histological and histomorphometrical study in the maxilla of pigsClinical Oral Implants Research, 2009
- Long‐term reaction to bone cement in osteoporotic bone: new bone formation in vertebral bodies after vertebroplastyJournal of Anatomy, 2008
- Problematic Bone Fixation with Pyrocarbon Implants in Proximal Interphalangeal Joint Replacement: Short-Term ResultsJournal of Hand Surgery (European Volume), 2006
- Osseointegration and Mechanical Stability of Pyrocarbon and Titanium Hand Implants in a Load-Bearing In Vivo Model for Small Joint ArthroplastyThe Journal of Hand Surgery, 2006