A capacitive two-phase flow slug detection system

Authors:

Abstract
A capacitive-type two-phase slug detection and characterization system has been developed. The main goal of this work consisted of developing a measurement technique that satisfies the following requirements: to be able to detect a wide range of liquid film thickness from a few millimeters up to the case when the channel is completely filled with water, to have a fast time response, to be nonintrusive and movable, to have a linear response for void fraction of up to 70%, and to be insensitive to the structure of the test section and to proximity effects. In order to detect very small changes in capacity required to fulfill these requirements, a nonlinear twin-T type bridge is used as the front end stage of the instrument. Furthermore, the linearity and stability response criteria are achieved by the appropriate selection of the geometry and topology of the electrodes; the calibration of the system shows an almost linear response for void fractions of up to 70%. The instrument is presently used to determine the slug propagation velocity and frequency in counter-current two-phase flow experiments.

This publication has 17 references indexed in Scilit: