Impact of Prosthesis‐Patient Mismatch on Left Ventricular Myocardial Mechanics After Transcatheter Aortic Valve Replacement
Open Access
- 23 February 2016
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 5 (2) , e002866
Abstract
Background: The aim of this study was to compare left ventricular ( LV ) remodeling using myocardial strain between patients with severe aortic stenosis ( AS ) treated with transcatheter aortic valve replacement ( TAVR ) with and without prosthesis‐patient mismatch ( PPM ). Methods and Results: In a retrospective study, speckle‐tracking echocardiography was used to measure global longitudinal strain ( GLS ) and strain rate ( GLSR ), circumferential strain, and rotation before and at mid‐term follow‐up post‐ TAVR . Moderate and severe PPM were defined as an effective orifice area ≤0.85 and 2 /m 2 , respectively. A total of 102 patients (median age, 83 years [77–88]) with severe AS were included. At 6±3 months post‐ TAVR , moderate and severe PPM were found in 32 (31%) and 9 (9%) patients. Patients without PPM had a significant regression in LV mass (from 134±41 to 119±38 g/m 2 ; P =0.001) at follow‐up whereas those with PPM did not. There was a significant improvement in LV GLS (−12.8±4.0 to −14.3±4.3%; P =0.01), GLSR (−0.61±0.20 to −0.73±0.25 second −1 ; P −1 ; P <0.001) in patients without PPM , but not in those with PPM . After adjustment for pre‐ TAVR ejection fraction and post‐ TAVR aortic regurgitation, patients without PPM had greater improvement in LV longitudinal strain parameters compared to those with PPM . After a median follow‐up of 46.1 months (interquartile range, 35.4–60.8), there was no difference in survival between patients with and without PPM . Conclusions: TAVR was associated with an incidence of PPM of 40%. Greater reverse LV remodeling using myocardial strain was evident in patients without PPM compared to PPM . Presence of PPM was not associated with mortality.Keywords
This publication has 35 references indexed in Scilit:
- Recovery of Left Ventricular Mechanics after Transcatheter Aortic Valve Implantation: Effects of Baseline Ventricular Function and Postprocedural Aortic RegurgitationJournal of the American Society of Echocardiography, 2014
- Incidence and Sequelae of Prosthesis-Patient Mismatch in Transcatheter Versus Surgical Valve Replacement in High-Risk Patients With Severe Aortic StenosisJACC, 2014
- A critical review of hemodynamic changes and left ventricular remodeling after surgical aortic valve replacement and percutaneous aortic valve replacementAmerican Heart Journal, 2014
- Comparison of Transcatheter and Surgical Aortic Valve Replacement in Severe Aortic StenosisJACC, 2013
- Left Ventricular Global Systolic Longitudinal Deformation and Prognosis 1 Year after Femoral and Apical Transcatheter Aortic Valve ImplantationJournal of the American Society of Echocardiography, 2013
- Three-Dimensional Speckle-Tracking Analysis of Left Ventricular Function after Transcatheter Aortic Valve ImplantationJournal of the American Society of Echocardiography, 2012
- Two-Year Outcomes after Transcatheter or Surgical Aortic-Valve ReplacementNew England Journal of Medicine, 2012
- Current and Evolving Echocardiographic Techniques for the Quantitative Evaluation of Cardiac Mechanics: ASE/EAE Consensus Statement on Methodology and IndicationsJournal of the American Society of Echocardiography, 2011
- Prosthesis-Patient Mismatch: An UpdateCurrent Cardiology Reports, 2011
- Comparison of the Hemodynamic Performance of Percutaneous and Surgical Bioprostheses for the Treatment of Severe Aortic StenosisJACC, 2009