Thyroid fine needle aspiration cytology processed by ThinPrep: an additional slide decreased the number of inadequate results
- 5 March 2010
- journal article
- Published by Wiley in Cytopathology
- Vol. 21 (2) , 97-102
Abstract
E. D. Rossi, F. Morassi, G. Santeusanio, G. F. Zannoni and G. Fadda Thyroid fine needle aspiration cytology processed by ThinPrep: an additional slide decreased the number of inadequate resultsBackground: Fine needle aspiration cytology is the most accurate tool for diagnosing thyroid nodules. Its accuracy is related to the rate of inadequate samples, which can be minimized with the adoption of on‐site assessment of the adequacy of the material. The introduction of liquid‐based cytology (LBC) in the thyroid does not allow checking on the adequacy of the cellularity. The possibility of making a second LBC slide for decreasing the number of non‐diagnostic cases is studied.Methods: Out of 553 cases diagnosed in a single institution from January to March 2005, 166 consecutive cases with an LBC slide reviewed by the same pathologist were evaluated. The cases were classified in a five‐tiered category system (Thy1 to 5 according to the British Thyroid Association guidelines) and all but two (with cystic degeneration) were processed by LBC and stained with Papanicolaou stain. The above‐mentioned categories are defined as follows: Thy1 inadequate or haemorrhagic, Thy2 non‐neoplastic lesion; Thy3 follicular lesion/suspected follicular neoplasm; Thy4 suspicious for malignancy; Thy5 diagnostic of malignancy. For each case the cytological diagnosis was made on the LBC slide and the adequacy of the cellularity for a conclusive diagnosis was assessed.Results: Of the 166 cases, 39 were non‐diagnostic (Thy1—inadequate), ten presented features of cystic degeneration (Thy1—haemorrhagic), 90 were benign (Thy2), 22 were diagnosed as a follicular lesion (Thy3), one as suspicious of malignancy (Thy4) and four as papillary carcinoma (Thy5). Thirty‐nine cases had a second LBC for achieving a definitive diagnosis with eventual re‐classification. Of these cases, 23 (61.5%) led to a conclusive diagnosis (18 Thy2, five Thy3) with a 18.5% decrease of the inadequacy rate.Conclusions: The making of an additional LBC slide helps in achieving a diagnosis in cases classified as non‐diagnostic on the first standard slide (52.1% recovery rate). This procedure is particularly helpful for meeting the adequacy criteria in benign and indeterminate lesions and could also be used for refining the diagnosis of suspicious for a malignant thyroid neoplasm.Keywords
This publication has 23 references indexed in Scilit:
- Comparison of Thin-Prep and cell block preparation for the evaluation of Thyroid epithelial lesions on fine needle aspiration biopsyCytojournal, 2008
- Cellular adequacy for thyroid aspirates prepared by ThinPrep: How many cells are needed?Diagnostic Cytopathology, 2007
- Do we need more than one ThinPrep to obtain adequate cellularity in fine needle aspiration?Diagnostic Cytopathology, 2007
- Usefulness of repeated fine-needle cytology in the follow-up of non-operated thyroid nodulesEuropean Journal of Endocrinology, 2007
- The value of onsite adequacy assessment of thyroid fine-needle aspirations is a function of operator experienceCancer, 2006
- Cost-Effectiveness of Immediate Specimen Adequacy Assessment of Thyroid Fine-Needle AspirationsAmerican Journal of Clinical Pathology, 2004
- ThinPrep® for cytologic evaluation of follicular thyroid lesions: Correlation with histologic findingsDiagnostic Cytopathology, 2003
- Thyroid fine needle aspiration: the morphological features on ThinPrep® slide preparations. Eighty cases with histological controlCytopathology, 2003
- Evidence-Based Criteria for Adequacy in Thyroid Fine-Needle AspirationAmerican Journal of Clinical Pathology, 2002
- Cytologic artifacts and pitfalls of thyroid fine-needle aspiration using ThinPrep®Cancer, 2001