Hip Resurfacing Femoral Neck Fracture Influenced by Valgus Placement
Authors:
- Bassam A MasriBMBassam A Masri
- Jérôme TonettiJTJérôme Tonetti
- Antony J HodgsonAHAntony J Hodgson
- Nelson V GreidanusNGNelson V Greidanus
- 1 December 2007
- journal article
- research article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 465, 71-79
Abstract
Femoral neck fracture is the most common short-term concern after hip resurfacing arthroplasty. Currently, there is little basis to decide between neutral and valgus placement. We loaded 10 notched cadaveric femur pairs to failure; one side was implanted at 0 degrees relative to the femoral neck and the other at 10 degrees valgus. All 20 were dual-energy X-ray absorptiometry-scanned. Failure load correlated with bone mineral density. Valgus placement increased the fracture load by an average of 28% over neutral for specimens with normal bone mineral density but had no effect on fracture load in specimens with low bone mineral density. For specimens with normal bone mineral density (typical of patients undergoing resurfacing arthroplasty), neutral-valgus placement had a greater effect than bone mineral density, explaining 54% of the fracture load variance. Component placement greater than 10 degrees valgus is likely undesirable because this can lead to an increase in component size and a greater likelihood of notching. To reduce fracture risk, we recommend placing the femoral component in valgus and selecting patients with higher bone mineral density.Keywords
This publication has 29 references indexed in Scilit:
- Surgical Variables Affect the Mechanics of a Hip Resurfacing SystemClinical Orthopaedics and Related Research, 2006
- The Nonoperative Management of Periprosthetic Fractures Associated With the Birmingham Hip Resurfacing ProcedureThe Journal of Arthroplasty, 2005
- Femoral neck fractures following Birmingham hip resurfacingThe Journal of Bone and Joint Surgery. British volume, 2005
- Early results of primary Birmingham hip resurfacingsThe Journal of Bone and Joint Surgery. British volume, 2005
- Birmingham hip resurfacing arthroplastyThe Journal of Bone and Joint Surgery. British volume, 2005
- Computer-assisted femoral head resurfacingComputer Aided Surgery, 2005
- Metal-on-metal surface arthroplasty with a cemented femoral component*1A 7–10 year follow-up studyThe Journal of Arthroplasty, 2004
- Predictive geometric factors in a standardized model of femoral neck fractureInjury, 2002
- Biomechanical study of the resurfacing hip arthroplastyThe Journal of Arthroplasty, 2000
- The Femoral Head Remnant in Resurfacing Arthroplasty1982