Modification and refinement of astigmatism in keratoconic eyes with intrastromal corneal ring segments
Authors:
- Jorge L. AlióJAJorge L. Alió
- Miguel A. TeusMTMiguel A. Teus
- Rafael I. BarraquerRBRafael I. Barraquer
- Ralph MichaelRMRalph Michael
- Ramón JiménezRJRamón Jiménez
- 1 September 2010
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 36 (9) , 1562-1572
Abstract
To analyze corneal astigmatic changes after implantation of intrastromal corneal ring segments (ICRS) in keratoconic eyes using the Alpins vectorial method. Vissum Corporation, Alicante, Spain. Keraring ICRS were implanted in eyes with a diagnosis of keratoconus. One of 3 surgeons performed the ICRS implantations using femtosecond technology and following the same protocol. Visual, refractive, keratometric, and corneal aberrometric changes were evaluated during a 12-month follow-up. Corneal astigmatic changes were also analyzed using the following Alpins vectorial components: targeted induced astigmatism (TIA), surgically induced astigmatism (SIA), difference vector, magnitude of error, flattening effect, and torque. Postoperatively, there was significant visual improvement (P = .03), significant central flattening (P = .03), and a significant reduction in manifest astigmatism (P<.01). The magnitude of SIA vector was significantly lower than the TIA postoperatively (P>or=.02). The mean magnitude of the difference vector 3 months postoperatively was +2.96 diopters (D) +/- 1.68 (SD). The mean magnitude of error remained negative and unchanged (P>or=.10). The mean magnitude of the flattening effect was significantly lower than the TIA at all postoperative visits (P<or=.01). The mean magnitude of torque vector was 1.21 +/- 0.98 D at 3 months. Significant negative correlations were found between preoperative corneal astigmatism and the magnitude of error and difference vector at all postoperative visits. Although ICRS implantation significantly reduced the magnitude of corneal astigmatism, there was a trend toward undercorrection and the meridian of correction was not appropriate in all cases, showing the need for nomogram adjustments.Keywords
This publication has 44 references indexed in Scilit:
- A comparison of induced astigmatism in 20- vs 25-gauge vitrectomy proceduresEye, 2009
- Outcomes of Epi-LASIK for the Correction of High Myopia and Myopic Astigmatism after More than 1 YearOphthalmologica, 2008
- Intacs implantation using a femtosecond laser for management of keratoconus: Comparison of 306 cases in different stagesJournal of Cataract & Refractive Surgery, 2008
- Clinical outcomes of laser in situ keratomileusis using combined topography and refractive wavefront treatments for myopic astigmatismJournal of Cataract & Refractive Surgery, 2008
- Surgically induced astigmatism after biaxial phacoemulsification compared to coaxial phacoemulsificationEye, 2008
- Intracorneal ring segment implantation for the management of keratoconus: Safety and efficacyJournal of Cataract & Refractive Surgery, 2007
- Intracorneal ring segments for keratoconus correction: Long-term follow-upJournal of Cataract & Refractive Surgery, 2006
- Analysis of results related to good and bad outcomes of Intacs implantation for keratoconus correctionJournal of Cataract & Refractive Surgery, 2006
- European clinical evaluation: Use of Intacs for the treatment of keratoconusJournal of Cataract & Refractive Surgery, 2006
- Modified Intracorneal Ring Segment Implantations (INTACS) for the Management of Moderate to Advanced KeratoconusCornea, 2006