Energy and Exergy Analysis of a 348.5 MW Steam Power Plant
Authors:
- 26 March 2010
- journal article
- research article
- Published by Taylor & Francis in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
- Vol. 32 (11) , 1016-1027
Abstract
In the present work, the energy and exergy analysis of Kostolac power plant in Serbia is presented. The primary objectives of this article are to analyze the system components separately and to identify and quantify the sites having the largest energy and exergy losses. The energy and exergy efficiency is calculated using the plant operating data from the plant at different loads. The load variation is studied with the data at 100% and 60% of full load. Moreover, the effects of the load variations are calculated in order to obtain a good insight into this analysis. The performance of the plant is estimated by a component-wise modeling, and a detailed break-up of energy and exergy losses for the considered plant has been presented. The results show that energy losses have mainly occurred in the condenser where 421 MW is lost to the environment while only 105.78 MW has been lost from the boiler. Nevertheless, the irreversibility rate of the boiler is higher than the irreversibility rates of the other components. The percentage ratio of the exergy destruction to the total exergy destruction was found to be maximum in the boiler system (88.2%) followed by the turbines (9.5%), and then the forced draft fan condenser (0.5%). In addition, the calculated thermal efficiency based on the lower heating value of fuel was 39% while the exergy efficiency of the power cycle was 35.77%.Keywords
This publication has 10 references indexed in Scilit:
- Exergy analysis of a 420 MW combined cycle power plantInternational Journal of Energy Research, 2007
- Effect of ambient temperature on the efficiency of the regenerative and reheat Çatalağzı power plant in TurkeyApplied Thermal Engineering, 2007
- Concept on thermoeconomic evaluation of steam turbinesApplied Thermal Engineering, 2007
- Exergy analysis of a coal-based 210 MW thermal power plantInternational Journal of Energy Research, 2006
- Energy-exergy analysis and modernization suggestions for a combined-cycle power plantInternational Journal of Energy Research, 2005
- On the thermoeconomic approach to the diagnosis of energy system malfunctionsPart 1: the TADEUS problemEnergy, 2004
- Thermoeconomic analysis of power plants: an application to a coal fired electrical generating stationEnergy Conversion and Management, 2003
- Structural theory and thermoeconomic diagnosisEnergy Conversion and Management, 2002
- Steady-state thermodynamic analysis of a combined Carnot cycle with internal irreversibilityEnergy, 1995
- A Method for Predicting the Performance of Steam Turbine-Generators....: 16,500 kw and LargerJournal of Engineering for Power, 1963