Conceptual Design of a UVC-LED Air Purifier to Reduce Airborne Pathogen Transmission—A Feasibility Study
Open Access
Abstract
Existing indoor closed ultraviolet-C (UVC) air purifiers (UVC in a box) have faced technological challenges during the COVID-19 breakout, owing to demands of low energy consumption, high flow rates, and high kill rates at the same time. A new conceptual design of a novel UVC-LED (light-emitting diode) air purifier for a low-cost solution to mitigate airborne diseases is proposed. The concept focuses on performance and robustness. It contains a dust-filter assembly, an innovative UVC chamber, and a fan. The low-cost dust filter aims to suppress dust accumulation in the UVC chamber to ensure durability and is conceptually shown to be easily replaced while mitigating any possible contamination. The chamber includes novel turbulence-generating grids and a novel LED arrangement. The turbulent generator promotes air mixing, while the LEDs inactivate the pathogens at a high flow rate and sufficient kill rate. The conceptual design is portable and can fit into ventilation ducts. Computational fluid dynamics and UVC ray methods were used for analysis. The design produces a kill rate above 97% for COVID and tuberculosis and above 92% for influenza A at a flow rate of 100 L/s and power consumption of less than 300 W. An analysis of the dust-filter performance yields the irradiation and flow fields.Keywords
Funding Information
- Royal Academy of Engineering (EXPP2021\1\247)
This publication has 36 references indexed in Scilit:
- Computational fluid dynamics modelling and optimisation of an upper-room ultraviolet germicidal irradiation system in a naturally ventilated hospital wardIndoor and Built Environment, 2014
- Potential for airborne transmission of infection in the waiting areas of healthcare premises: stochastic analysis using a Monte Carlo modelBMC Infectious Diseases, 2010
- Computational modeling of ultraviolet disinfectionWater Science & Technology, 2010
- Upper-Room Ultraviolet Light and Negative Air Ionization to Prevent Tuberculosis TransmissionPLOS Medicine, 2009
- Grid-generated turbulence revisitedFluid Dynamics Research, 2009
- How far droplets can move in indoor environments ? revisiting the Wells evaporation?falling curveIndoor Air, 2007
- Photokeratitis and Other Phototoxic Effects on the Cornea and ConjunctivaInternational Journal of Toxicology, 2002
- Clogging of fibrous filters by solid aerosol particles Experimental and modelling studyChemical Engineering Science, 2001
- Particle response and turbulence modification in fully developed channel flowJournal of Fluid Mechanics, 1994
- Zonal Two Equation k-w Turbulence Models For Aerodynamic Flows1993