Evaluation of a Closed-End Coaxial High-Purity Germanium Cylindrical Detector Efficiency Using a Simplified Geometrical Approach
- 1 October 2009
- journal article
- research article
- Published by Taylor & Francis in Nuclear Technology
- Vol. 168 (1) , 41-44
Abstract
The full-energy peak (photopeak) efficiency and peak-to-total ratio of a closed-end coaxial high-purity germanium detector were calculated and compared with the experimental measurements in the energy range between 60 and 1863 keV. The attenuation of photons by the source itself (self-absorption), the source container, and the detector end cap materials is also included. Many experimental readings have been taken for the source-detector system used in this investigation. By comparison, the calculated and experimental full-energy peak efficiency and peak-to-total ratio values are in good agreement; the overall percentage error is <3%.Keywords
This publication has 20 references indexed in Scilit:
- Analytical calculation of the efficiencies of gamma scintillators. Part I: Total efficiency for coaxial disk sourcesRadiation Physics and Chemistry, 1998
- Source-detector geometrical efficiencyRadiation Physics and Chemistry, 1994
- Applicability of the analytical functions and semi-empirical formulae to the full energy peak efficiency of large volume HPGe gamma detectorsJournal of Physics D: Applied Physics, 1991
- A simple semi-empirical way of accounting for the contribution of pair production process to the efficiency of Ge detectorsJournal of Physics D: Applied Physics, 1991
- An empirical method for peak-to-total ratio computation of a gamma-ray detectorNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1989
- Gamma-ray response functions for scintillation and semiconductor detectorsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1989
- A comparison of empirical and semiempirical efficiency calculations for Ge detectorsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1989
- Linear classes of Ge(Li) detector efficiency functionsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1985
- Calculation of the absolute peak efficiency of gamma-ray detectors for different counting geometriesNuclear Instruments and Methods in Physics Research, 1981
- Monte Carlo calculation of efficiencies of right-circular cylindrical NaI detectors for arbitrarily located point sourcesNuclear Instruments and Methods, 1978