Control of Doubly Fed Induction Generator under symmetrical voltage dips
- 1 June 2008
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21635137,p. 2456-2462
Abstract
Doubly Fed Induction Generator (DFIG) is largely used in wind generators. It provides variable speed characteristics in a cost-effective way. The main drawback of this machine is its sensitivity to grid disturbances. Voltage dips cause overvoltages to appear in the rotor that can surpass the converter limits. Additionally, variations of the grid voltage cause the stator flux to oscillate at the grid frequency. This paper proposes a novel control strategy to overcome these problems; furthermore, it reduces the rotor voltage, improving the control of the rotor current and it accelerates the dumping of the flux oscillations.Keywords
This publication has 5 references indexed in Scilit:
- About the active and reactive power measurements in unsymmetrical voltage dip ride‐through testingWind Energy, 2007
- Dynamic Behavior of the Doubly Fed Induction Generator During Three-Phase Voltage DipsIEEE Transactions on Energy Conversion, 2007
- Design and implementation of a closed-loop observer and adaptive controller for induction motor drivesIEEE Transactions on Industry Applications, 1998
- Variable-frequency synchronous motor drives for electric vehiclesIEEE Transactions on Industry Applications, 1996
- A physically insightful approach to the design and accuracy assessment of flux observers for field oriented induction machine drivesIEEE Transactions on Industry Applications, 1994