Limitations of glomerular filtration rate equations in the renal transplant patient
Authors:
- 1 March 2005
- journal article
- research article
- Published by Wiley in Clinical Transplantation
- Vol. 19 (2) , 259-268
Abstract
Abstract: This study aims to compare the performance of endogenous creatinine clearance (CLcr) and a number of published mathematical equations to calculate glomerular filtration rate (GFR) in renal transplant patients considering99mTc DTPA isotope scan as the reference method. A total of 152 GFR were performed on 81 renal transplant patients. Accuracy of each method was measured at different percentiles. The bias and precision of all the methods were then compared. A pairedt‐test was used to compare the performance of each calculation to the respective GFR measured by isotope study performed on the same day. In the total population, all calculated methods correlated significantly with the isotope results. Accuracies within specific ranges of the isotope GFR were limited in all equations (agreement with isotope result ≤72% at 30% accuracy range in the total group). Within the limited accuracy, Edwards’ equation (K.D. Edwards and H.M. Whyte,Australas Ann Med1959; vol. 8: p. 218) had the least bias in the total population. Bjornsson (T.D. Bjornsson,Clin Pharmacokinet1979; vol. 4: p. 200) had the least bias in patients with GFR ≥ 50 mL/min and Gates in patients with GFR < 50 mL/min. Salazar (D.E. Salazar and G.B. Corcoran,Am J Med1988; vol. 84: p. 1053) had the least bias in patients with BMI above 30 kg/m2and the Davis equation (G.A. Davis and M.H. Chandler,Am J Health Syst Pharm1996; vol. 53: p. 1028) in patients with BMI 2. In all analyses, Nankivell (B.J. Nankivell, S.M. Gruenwald, R.D.M. Allen and J.R. Chapman,Transplantation1995; vol. 59: p. 1683) overestimated GFR by more than 80% and MDRD 1 and 2 in <10% of the time. The results demonstrate the inherited limitation in the currently available equations to calculate GFR in renal transplant patients.Keywords
This publication has 42 references indexed in Scilit:
- Assessing renal graft function in clinical trials: Can tests predicting glomerular filtration rate substitute for a reference method?Kidney International, 2004
- A More Accurate Method To Estimate Glomerular Filtration Rate from Serum Creatinine: A New Prediction EquationAnnals of Internal Medicine, 1999
- Utility of Radioisotopic Filtration Markers in Chronic Renal Issufficiency: Simultaneous Comparison of 125I-Iothalamate, 169Yb-DTPA, 99mTc-DTPA, and InulinAmerican Journal of Kidney Diseases, 1990
- Predicting creatinine clearance and renal drug clearance in obese patients from estimated fat-free body massThe American Journal of Medicine, 1988
- Creatinine Clearance Estimation From Serum Creatinine Values: An Analysis of Three Mathematical Models of Glomerular FunctionAmerican Journal of Kidney Diseases, 1985
- Simultaneous Measurement of Renal Clearance and Plasma Clearance of 99mTc-Labelled Diethylenetriaminepenta-Acetate, 51Cr-Labelled Ethylenediaminetetra-Acetate and Inulin in ManClinical Science, 1984
- Influence of range of renal function and liver disease on predictability of creatinine clearanceClinical Pharmacology & Therapeutics, 1981
- Creatinine Clearance: Bedside EstimateAnnals of Internal Medicine, 1973
- A computer program for estimation of creatinine clearance from unstable serum creatinine levels, age, sex, and weightMathematical Biosciences, 1972
- COMPUTER-ASSISTED PRESCRIBING OF KANAMYCIN FOR PATIENTS WITH RENAL INSUFFICIENCYThe Lancet, 1972