Accuracy and Reliability of Extubation Decisions by Intensivists
Open Access
- 1 July 2011
- journal article
- Published by SAGE Publications in Respiratory Care
- Vol. 56 (7) , 920-927
Abstract
BACKGROUND: Mortality increases when extubations fail. Although predictors of extubation failure have been evaluated, physicians' reasoning to extubate a patient has received minimal attention. We hypothesized that the accuracy and reliability of physicians' extubation decisions are low. METHODS: We sent surveys to 55 physicians in the divisions of pulmonary and critical care medicine of 3 teaching hospitals in Chicago, Illinois. The survey comprised 32 clinical vignettes of real patients who were extubated after they tolerated a spontaneous breathing trial (16 failed extubations). Unaware of the outcomes of extubation, the physicians were asked if they would extubate each patient, and to give reasons if they opted not to. We quantified the agreement between and accuracy of the physicians' decisions, determined the patient characteristics that influence the extubation decision, and described the tradeoffs leading to that decision. RESULTS: Completed surveys were obtained from 45 physicians (82%). The physicians postponed extubation in 37% of the cases. Agreement between any 2 physicians was fair (mean ± SD phi 0.34 ± 0.15) and was highest between attending physicians from the same institution (0.37 ± 0.15). In deciding to extubate a patient, 33% of the physicians relied on the breathing pattern on pressure support ventilation, 49% relied on the acid-base status, 13% relied on the mental status, and 8% relied on the amount of secretions. The accuracy of the physicians' extubation decisions was low (area under the receiver operating characteristic curve 0.35). The sensitivity of the physicians identifying the patients who were successfully extubated was 57%, and the specificity was 31%. A model that comprises the same variables that influenced the physicians was more accurate in predicting extubation outcome (area under the receiver operating characteristic curve 0.88). CONCLUSIONS: For a decision made on an almost daily basis in intensive care units, physicians' extubation decisions are inaccurate and only fairly reliable.Keywords
This publication has 25 references indexed in Scilit:
- Variable performance of weaning-predictor tests: role of Bayes' theorem and spectrum and test-referral biasIntensive Care Medicine, 2006
- Computer-driven management of prolonged mechanical ventilation and weaning: a pilot studyIntensive Care Medicine, 2005
- National questionnaire survey on what influences doctors' decisions about admission to intensive careBMJ, 2004
- Neurologic status, cough, secretions and extubation outcomesIntensive Care Medicine, 2004
- Variability in interventions with pulmonary artery catheter dataIntensive Care Medicine, 2003
- Decision to extubateIntensive Care Medicine, 2002
- Advances in Mechanical VentilationNew England Journal of Medicine, 2001
- Daily Interruption of Sedative Infusions in Critically Ill Patients Undergoing Mechanical VentilationNew England Journal of Medicine, 2000
- Effect on the Duration of Mechanical Ventilation of Identifying Patients Capable of Breathing SpontaneouslyNew England Journal of Medicine, 1996
- A Prospective Study of Indexes Predicting the Outcome of Trials of Weaning from Mechanical VentilationNew England Journal of Medicine, 1991