Evaluation of Alere i Influenza A&B for Rapid Detection of Influenza Viruses A and B
Authors:
Open Access
- 1 September 2014
- journal article
- research article
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 52 (9) , 3339-3344
Abstract
Rapid and accurate diagnosis of influenza is important for infection control, as well as for patient management. Alere i Influenza A&B is an isothermal nucleic acid amplification-based integrated system for detection and differentiation of influenza virus A and influenza virus B. The performance of the Alere i Influenza A&B was screened using frozen nasopharyngeal-swab specimens collected in viral transport medium (VTM) that were originally tested fresh with the FilmArray Respiratory Panel (RP) assay during the 2012–2013 influenza outbreak. In total, 360 VTM specimens were selected for Alere i Influenza A&B testing: 40 influenza virus A H1N1-2009 (influenza virus A-1), 40 influenza virus A H3N2 (influenza virus A-3), 37 influenza virus A “equivocal” or “no subtype detected” (influenza virus A-u), 41 influenza virus B, and 202 influenza virus-negative specimens, as initially determined by the FilmArray RP assay. The Alere assay showed sensitivities of 87.2%, 92.5%, 25.0%, and 97.4% for influenza virus A-1, influenza virus A-3, influenza virus A-u, and influenza virus B, respectively, after discordant resolution by Prodesse ProFLU+ PCR. The specificities were 100% for both influenza virus A and influenza virus B. In general, the Alere i Influenza A&B provided good sensitivity, although the assay did show poorer sensitivity with samples determined to have low influenza virus A titers by Prodesse ProFlu+ PCR (a mean real-time PCR threshold cycle [C T ] value of 31.9 ± 2.0), which included the majority of the samples called influenza virus A “equivocal” or “no subtype detected” by a single BioFire FilmArray RP test. The integrated, rapid, and simple characteristics of the Alere i Influenza A&B assay make it a potential candidate for point-of-care testing, with a test turnaround time of less than 15 min.Keywords
This publication has 27 references indexed in Scilit:
- Detection of Influenza A and B Viruses With the Sofia AnalyzerAmerican Journal of Clinical Pathology, 2013
- Evaluation of a rapid diagnostic test, NanoSign® Influenza A/B Antigen, for detection of the 2009 pandemic influenza A/H1N1 virusesVirology Journal, 2010
- Duplex Real-Time Reverse Transcriptase PCR Assays for Rapid Detection and Identification of Pandemic (H1N1) 2009 and Seasonal Influenza A/H1, A/H3, and B VirusesJournal of Clinical Microbiology, 2010
- Antigen-Based Assays for the Identification of Influenza Virus and Respiratory Syncytial Virus: Why and How to Use Them in Pediatric PracticeClinics In Laboratory Medicine, 2009
- Comparative evaluation of real-time PCR and conventional RT-PCR during a 2 year surveillance for influenza and respiratory syncytial virus among children with acute respiratory infections in Kolkata, India, reveals a distinct seasonality of infectionJournal of Medical Microbiology, 2009
- Rapid Multiplex Reverse Transcription-PCR Typing of Influenza A and B Virus, and Subtyping of Influenza A Virus into H1, 2, 3, 5, 7, 9, N1 (Human), N1 (Animal), N2, and N7, Including Typing of Novel Swine Origin Influenza A (H1N1) Virus, during the 2009 Outbreak in Milwaukee, WisconsinJournal of Clinical Microbiology, 2009
- Analytical and Clinical Sensitivity of the 3M Rapid Detection Influenza A+B AssayJournal of Clinical Microbiology, 2008
- Evaluation of the One-Step Multiplex Real-Time Reverse Transcription-PCR ProFlu-1 Assay for Detection of Influenza A and Influenza B Viruses and Respiratory Syncytial Viruses in ChildrenJournal of Clinical Microbiology, 2008
- Performance of six influenza rapid tests in detecting human influenza in clinical specimensJournal of Clinical Virology, 2007
- Survey on influenza laboratory diagnostic and surveillance methods in EuropeEuropean Journal of Epidemiology, 2000