Evaluation of a portable clinical analyzer for the determination of blood gas partial pressures, electrolyte concentrations, and hematocrit in venous blood samples collected from cattle, horses, and sheep
Authors:
- Juliana R. PeiróJPJuliana R. Peiró
- Alexandre S. BorgesABAlexandre S. Borges
- Roberto C. GonçalvesRGRoberto C. Gonçalves
- Luiz Claudio N. MendesLMLuiz Claudio N. Mendes
- 1 May 2010
- journal article
- Published by American Veterinary Medical Association (AVMA) in American Journal of Veterinary Research
- Vol. 71 (5) , 515-521
Abstract
Objective —To compare results reported for blood gas partial pressures, electrolyte concentrations, and Hct in venous blood samples collected from cattle, horses, and sheep and analyzed by use of a portable clinical analyzer (PCA) and reference analyzer (RA). Animals —Clinically normal animals (24 cattle, 22 horses, and 22 sheep). Procedures —pH; P co 2 ; P o 2 ; total carbon dioxide concentration; oxygen saturation; base excess; concentrations of HCO 3 − , Na + , K + , and ionized calcium; Hct; and hemoglobin concentration were determined with a PCA. Results were compared with those obtained for the same blood sample with an RA. Bias (mean difference) and variability (95% confidence interval) were determined for all data reported. Data were also subjected to analyses by Deming regression and Pearson correlation. Results —Analysis of Bland-Altman plots revealed good agreement between results obtained with the PCA and those obtained with the RA for pH and total carbon dioxide concentration in cattle, K + concentration in horses and sheep, and base excess in horses. Except for Na + concentration and Hct in horses and sheep, correlation was good or excellent for most variables reported. Conclusions and Clinical Relevance —Data from blood gas and electrolyte analyses obtained by use of the PCA can be used to evaluate the health status of cattle, horses, and sheep. Furthermore, the handheld PCA device may have a great advantage over the RA device as a result of the ability to analyze blood samples on farms that may be located far from urban centers.Keywords
This publication has 23 references indexed in Scilit:
- Measurement of ionized calcium in canine blood samples collected in prefilled and self‐filled heparinized syringes using the i‐STAT point‐of‐care analyzerVeterinary Clinical Pathology, 2008
- Agreement Between Methods of Measurement with Multiple Observations Per IndividualJournal of Biopharmaceutical Statistics, 2007
- Evaluation of the i-STAT Portable Clinical Analyzer in Chickens (Gallus Gallus)Journal of Veterinary Diagnostic Investigation, 2007
- Haematology, Blood Chemistry and Urine Parameters of Free‐Ranging Plains Viscachas (Lagostomus maximus) in Argentina Determined by Use of a Portable Blood Analyser (i‐STAT®) and Conventional Laboratory MethodsJournal of Veterinary Medicine Series A, 2007
- Use of the i-STAT portable clinical analyzer in miceLab Animal, 2006
- Accuracy of the i-STATTM bedside blood gas analyserEuropean Respiratory Journal, 1999
- Evaluation of the i-STAT™ system: A portable chemistry analyzer for the measurement of sodium, potassium, chloride, urea, glucose, and hematocritClinical Biochemistry, 1995
- The Evaluation of a Portable Clinical Analyzer in the Emergency DepartmentAmerican Journal of Clinical Pathology, 1993
- New technologies, critical care, and economic realitiesCritical Care Medicine, 1993
- Comparing Laboratory Tests Using the Difference Plot MethodVeterinary Clinical Pathology, 1993