Monte Carlo simulations for configuring and testing an analytical proton dose-calculation algorithm
Authors:
- Wayne NewhauserWNWayne Newhauser
- Jonas FontenotJFJonas Fontenot
- Yuanshui ZhengYZYuanshui Zheng
- Jerimy PolfJPJerimy Polf
- Uwe TittUTUwe Titt
- Nicholas KochNKNicholas Koch
- Xiaodong ZhangXZXiaodong Zhang
- Radhe MohanRMRadhe Mohan
- 10 July 2007
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 52 (15) , 4569-4584
Abstract
Contemporary treatment planning systems for proton radiotherapy typically use analytical pencil-beam algorithms - which require a comprehensive set of configuration data - to predict the absorbed dose distributions in the patient. In order to reduce the time required to prepare a new proton treatment planning system for clinical use, it was desirable to configure the planning system before measured beam data were available. However, it was not known if the Monte Carlo simulation method was a practical alternative to measuring beam profiles. The purpose of this study was to develop a model of a passively scattered proton therapy unit, to simulate the properties of the proton fields using the Monte Carlo technique and to configure an analytical treatment planning system using the simulated beam data. Additional simulations and treatment plans were calculated in order to validate the pencil-beam predictions against the Monte Carlo simulations using realistic treatment beams. Comparison of dose distributions in a water phantom revealed small dose difference and distances to agreement under the validation conditions. The total simulation time for generating the 768 beam configuration profiles was approximately 6 weeks using 30 nodes in a parallel processing cluster. The results of this study show that it is possible to configure and test a proton treatment planning system prior to the availability of measured proton beam data. The model presented here provided a means to reduce by several months the time required to prepare an analytical treatment planning system for patient treatments.Keywords
This publication has 36 references indexed in Scilit:
- Determination of output factors for small proton therapy fieldsMedical Physics, 2007
- Significant reduction of normal tissue dose by proton radiotherapy compared with three-dimensional conformal or intensity-modulated radiation therapy in Stage I or Stage III non–small-cell lung cancerInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2006
- Design tools for proton therapy nozzles based on the double-scattering foil techniqueRadiation Protection Dosimetry, 2005
- Benchmarking analytical calculations of proton doses in heterogeneous matterMedical Physics, 2005
- PD-088 Image-guided proton radiotherapy for medically inoperable stage I non-small cell lung cancerLung Cancer, 2005
- Monte Carlo simulation of a protontherapy platform devoted to ocular melanomaMedical Physics, 2005
- Influence of multiple scattering and energy loss straggling on the absorbed dose distributions of therapeutic light ion beams: I. Analytical pencil beam modelPhysics in Medicine & Biology, 2004
- Secondary neutron and photon dose in proton therapyRadiotherapy and Oncology, 1998
- Monte Carlo and analytical calculation of proton pencil beams for computerized treatment plan optimizationPhysics in Medicine & Biology, 1997
- Instrumentation for treatment of cancer using proton and light-ion beamsReview of Scientific Instruments, 1993