New Type of Glucose Sensor Based on Enzymatic Conversion of Gel Volume into Liquid Column Length
Authors:
- Hiroaki SuzukiHSHiroaki Suzuki
- Ayumi KumagaiAKAyumi Kumagai
- Kazuyoshi OgawaKOKazuyoshi Ogawa
- Etsuo KokufutaEKEtsuo Kokufuta
- 20 January 2004
- journal article
- research article
- Published by American Chemical Society (ACS) in Biomacromolecules
- Vol. 5 (2) , 486-491
Abstract
A way to convert the volume change of a biochemo-mechanical gel into the change in liquid column length was developed. Our trial sensor device consisted of a small compartment for incorporating the gel, a flow channel with a filled dye solution, and a poly(dimethylsiloxane) (PDMS) diaphragm by which the gel and the dye solution were separated. A lightly cross-linked N-isopropylacrylamide (NIPAAm)/acrylic acid (AA) copolymer gel with immobilized glucose oxidase was used as a sensing element. It was found that a change in the gel volume caused by the immobilized enzyme reaction was accurately converted into a change of the column length (Δl) with the help of the PDMS diaphragm. By use of a cylindrical gel (diameter ∼2 and thickness ∼1 mm), the time curve of Δl varied depending upon glucose concentration over a range of 0.2−50 mM; in particular, it is of importance that semilogarithmic plots of Δl (in mm) against glucose concentration (in mM) can be used as a calibration curve. For glucose solutions of mM order, 1 min was enough to determine the concentrations, whereas 10 min was required for concentrations of μM order. When the measurement time was limited within 10 min, the lower detection limit was 200 μM. The response was affected by buffering capacity of the samples, but this was controllable through reduction of the sample volume. These results indicate that the present way can be used for the determination of glucose concentration.Keywords
This publication has 12 references indexed in Scilit:
- Phase transition in gels of sub-millimeter size induced by interaction with stimuli2005
- A disposable “intelligent mosquito” with a reversible sampling mechanism using the volume-phase transition of a gelSensors and Actuators B: Chemical, 2002
- Microfluidic tectonics: A comprehensive construction platform for microfluidic systemsProceedings of the National Academy of Sciences, 2000
- Influence of Freely Mobile Grafted Chain Length on Dynamic Properties of Comb-Type Grafted Poly(N-isopropylacrylamide) HydrogelsMacromolecules, 1995
- Comb-type grafted hydrogels with rapid deswelling response to temperature changesNature, 1995
- Construction of a biochemo-mechanical system using enzyme-loaded polyelectrolyte gelsPolymer Gels and Networks, 1994
- Structural features in epoxy networks from N-diglycidyl epoxies and amines: 1. Dominant intramolecular cyclization reaction in the reactions of N,N-diglycidylaniline with aniline and substituted anilinesPolymer, 1991
- Volume transition in a gel driven by hydrogen bondingNature, 1991
- Microcalorimetric detection of lower critical solution temperatures in aqueous polymer solutionsThe Journal of Physical Chemistry, 1990
- Kinetics of discontinuous volume–phase transition of gelsThe Journal of Chemical Physics, 1988