Design and analysis of DC/AC inverter using passive LCL filter with damping circuit configuration
- 1 August 2017
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 46-51
Abstract
This paper presents the study and analysis on the impacts of the insertion of a damper circuit in an LCL passive filter utilized to filter DC/AC inverter's output voltage. The damper is used to reduce peak resonance on its frequency response curves. The existing resonance frequency can make the filtered inverter output voltage become weak and unstable. One of existing solutions to overcome this problem is proposed by using of a damping resistor. Damping method can be applied using various configurations. However, this paper only discussed two damping configurations, namely series and parallel damping configuration. We use three criteria to analyze the impacts of the damper circuits, i.e. its capability of reducing total harmonic distortions (THDs), to maintain the output voltage and to improve output power of the inverter. Theoretically, the damper can reduce its peak resonance frequency. However, in any circumstance, it can potentially reduce the inverter's power, voltage output amplitude, and cannot improve its THD reduction.Keywords
This publication has 5 references indexed in Scilit:
- Topologies, generalized designs, passive and active damping methods of switching ripple filters for voltage source inverter: A comprehensive reviewRenewable and Sustainable Energy Reviews, 2016
- A Robust Passive Damping Method for LLCL-Filter-Based Grid-Tied Inverters to Minimize the Effect of Grid Harmonic VoltagesIEEE Transactions on Power Electronics, 2014
- Passive L and LCL filter design method for grid-connected inverters2014
- Optimal Design of LCL Harmonic Filters for Three-Phase PFC RectifiersIEEE Transactions on Power Electronics, 2013
- A New Design Method for the Passive Damped LCL and LLCL Filter-Based Single-Phase Grid-Tied InverterIEEE Transactions on Industrial Electronics, 2012