High-Quality Immunohistochemical Stains Through Computational Assay Parameter Optimization
- 13 February 2019
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 66 (10) , 2952-2963
Abstract
Accurate profiling of tumors using immunohistochemistry (IHC) is essential in cancer diagnosis. The inferences drawn from IHC-stained images depend to a great extent on the quality of immunostaining, which is in turn affected strongly by assay parameters. To optimize assay parameters, the available tissue sample is often limited. Moreover, with current practices in pathology, exploring the entire assay parameter space is not feasible. Thus, the evaluation of IHC stained slides is conventionally a subjective task, in which diagnoses are commonly drawn on images that are suboptimal. In this work, we introduce a framework to analyze IHC staining quality and its sensitivity to process parameters. To that extent, first histopathological sections are segmented automatically. Then, machine learning techniques are employed to extract disease-specific staining quality metrics (SQMs) targeting a quantitative assessment of staining quality. Finally, an approach to efficiently analyze the parameter space is introduced to infer sensitivity to process parameters. We present results on microscale IHC tissue samples of five breast tumor classes, based on disease state and protein expression. A disease-type classification F1-score of 0.82 and a contrast-level classification F1-score of 0.95 were achieved. With the proposed SQMs, an area under the curve of 0.85 was achieved on average over different disease types. Our methodology provides a promising step in automatically evaluating and quantifying staining quality of IHC stained tissue sections, and it can potentially standardize immunostaining across diagnostic laboratories.Keywords
Funding Information
- H2020 European Research Council (311122)
This publication has 36 references indexed in Scilit:
- The HER2 Receptor in Breast Cancer: Pathophysiology, Clinical Use, and New Advances in TherapyChemotherapy Research and Practice, 2012
- Quantitative comparison of immunohistochemical staining measured by digital image analysis versus pathologist visual scoringDiagnostic Pathology, 2012
- HER2 Evaluation and Its Impact on Breast Cancer Treatment DecisionsPublic Health Genomics, 2011
- Inappropriate calibration and optimisation of pan-keratin (pan-CK) and low molecular weight keratin (LMWCK) immunohistochemistry tests: Canadian Immunohistochemistry Quality Control (CIQC) experienceJournal of Clinical Pathology, 2011
- Image analysis as an adjunct to manual HER‐2 immunohistochemical review: a diagnostic tool to standardize interpretationHistopathology, 2010
- American Society of Clinical Oncology/College of American Pathologists Guideline Recommendations for Immunohistochemical Testing of Estrogen and Progesterone Receptors in Breast CancerJournal of Clinical Oncology, 2010
- Variance based sensitivity analysis of model output. Design and estimator for the total sensitivity indexComputer Physics Communications, 2010
- Rotation-invariant and scale-invariant Gabor features for texture image retrievalImage and Vision Computing, 2007
- Triangular Bernstein-Bézier patchesComputer Aided Geometric Design, 1986
- A trivariate clough—tocher scheme for tetrahedral dataComputer Aided Geometric Design, 1984