Determination of water content of crude oil by azeotropic distillation Karl Fischer coulometric titration
Authors:
- 30 May 2020
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 412 (19) , 4639-4645
Abstract
The determination of water content in crude oil is important for oil transportation, refining, and trade. However, the sensitivity and accuracy of the conventional azeotropic distillation (AD) method are inadequate. Karl Fischer titration methods may give false high results because of the reducing sulfur compounds in crude oil. The present study developed an azeotropic distillation Karl Fischer coulometric titration (AD-KFCT) method which required a modified instrument and a new calibration procedure. The method was modified to decrease the interference caused by reducing sulfur compounds. A certified reference material for water content in liquid was used to determine the recovery of water mass achieved using the AD-KFCT method. The effect of the sample polarity on the method accuracy was assessed. The relative error and relative standard deviations of the water content in three crude oils containing known amounts of water were −7.5% to 2.9% and 0.4% to 6.0%, respectively. The interference by reducing sulfur compounds was studied. The crude oil containing 1-propanethiol was measured using a sulfur dioxide-free anolyte, and the amount of iodine consumed by the distilled 1-propanethiol was determined. The contribution of 1-propanethiol was then subtracted from the water content measured using the normal Karl Fischer reagent. Finally, the relative error of the modified water content in the crude oil samples containing 1-propanethiol was −4.4% to 0.7%. Therefore, the modified AD-KFCT method is accurate and convenient for crude oil.Keywords
This publication has 20 references indexed in Scilit:
- Weak Signal Detection of the Crude Oil Moisture Content by Electromagnetic Conductance MethodApplied Mechanics and Materials, 2013
- Water content of pyrolysis oil: Comparison between Karl Fischer titration, GC/MS-corrected azeotropic distillation and 1H NMR spectroscopyJournal of Analytical and Applied Pyrolysis, 2011
- New and rapid analytical procedure for water content determination: Microwave accelerated Dean–StarkAnalytica Chimica Acta, 2009
- Electrostatic destabilization of water-in-crude oil emulsions: Application to a real case and evaluation of the Aibel VIEC technologyFuel, 2008
- A coulometric method for determining substances that interfere with the measurement of water in oils and other chemicals by the Karl Fischer methodAnalytical and Bioanalytical Chemistry, 2002
- Determination of water traces in various organic solvents using Karl Fischer method under FIA conditionsTalanta, 2000
- Determination of the Analytical Performance of a Headspace Capillary Gas Chromatographic Technique and Karl Fischer Coulometric Titration by System Calibration Using Oil Samples Containing Known Amounts of MoistureAnalytical Chemistry, 1999
- Stoichiometry and chemical metrology: Karl Fischer reactionAccreditation and Quality Assurance, 1999
- Determination of water in oil emulsions by a microwave resonance procedureAnalytical Chemistry, 1977
- The determination of small amounts of water in gases using Karl Fischer reagentThe Analyst, 1974